35009-2-1015
Page 55
Components
The gas valve is fitted with a manual HI/LO knob to allow for man-
ual modulation of the gas outlet pressure to the appliance burner.
The controls are designed to be used with either LPG or Natural
Gas and can be converted by use of an OEM supplied conversion
kit.
The Digital Fireplace Control (DFC) is an automatic gas ignition
system based on a single micro-controller core. This control man-
ages all functions related to ignition, flame sensing and supervi-
sion for atmospheric applications.
The DFC can be set to provide continuous or intermittent ignition
control sequences and flame monitoring with safety shutdown in
case of failure.
The DFC is set up as a stand alone (AC powered system with
battery back up. See Lighting Instructions on Page 54 and Wiring
Diagram on Page 53.
This appliance is only for use with the type of gas indicated on
the rating plate in this appliance and may be installed in an after-
market, permanently located, manufactured (mobile) home where
not prohibited by local codes. This appliance is not convertible for
use with other gases, unless a certified kit is used.
WARNING
Improper installation, adjustment, alteration, service or mainte-
nance can cause property damage, personal injury or loss of
life. Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
INTERMITTENT PILOT CONTROL SYSTEM TROUBLESHOOTING
Troubleshooting
Before proceeding with the procedures in the following trouble-
shooting table, verify that the power supply (AC/DC adapter) is
present and that the batteries inside the receiver and/or optional
battery pack are fresh and installed with correct polarity.
Make sure all the connections between the wire harnesses and
system components are proper and positive.
Verify that the static inlet pressure meets the manufacturer’s rec-
ommended inlet pressure. If necessary adjust the line pressure
regulator.
If the recommended actions for the following troubleshooting chart
do not help to address the problem consider replacing wiring har-
nesses.
WARNING
Any actions performed on the gas valve must be in accor-
dance with this instruction manual. Likewise, any actions
performed on the Digital Fireplace Control (DFC) or other
system components must be done in accordance with the
individual component instructions.
Replacement of components must be performed in accor-
dance with this instructions manual.