Slimline
www.whisperkool.com | Page 13
STEP 7
Slide the cooling unit in from the cellar side
with the controller facing inside. Secure the two
brackets to the wall through the pre-drilled holes.
The screws should penetrate the studs and/or
frame. Seal all cracks and gaps around the unit
with an airtight sealant or caulking to prevent air
leakage.
Note: If you use decorative moulding, it should be
attached to the walls, never to the cooling unit itself.
STEP 8
Attach the condensate drain line
The condensation drain line tube is used to remove excess condensation from the unit to a proper discharge location.
It is important that the drain line tube be properly connected to prevent leakage and other problems associated with
excess condensation.
Note: To prevent mold from growing, allow the drain line to hang above the water line.
Failure to install the drain line will void the warranty.
To prevent mold from growing, allow the drain line to
hang above the water line.
STEP 9
If removed, reinstall the grilles on both sides of the unit and plug in the power cord. The use of an extension cord is
not recommended.
Drain line is
above possible
water level
INSTALLATION (continued)
CELLAR SIDE
Bottle Probe
Power
Drain line
WRONG: Drain line
is under water.