WALL-MOUNTED UNIT SPECIFICATIONS
Filter grille
Evaporator unit
*Each c
ellar is unique and has specific c
ooling requirements. Heat load calculations should always be performed prior to selecting a cooling unit.
Model
Platinum Split Wall Mount
8
000
(Fan Coil Unit)
Platinum Split
8
000
H.E.
Condenser
(Air-Cooled Condensing Unit)
Dimensions
Refrigerant
R-134a
Condensing Unit HP
0.7 HP
Voltage Rating
120V (15-amp dedicated circuit required)
Weight (lbs)
5
4
5
6
Amps
2.2
Running Amp
s
Line Set
Liquid line 1/4" OD; Suction line 1/2" OD (less than 50ft.), 5/8" (greater than 50.ft)
Drain Line
1/2” ID clear plastic tubing (not included)
Installation
Evaporator unit is installed in the cellar. Condensing unit can be installed up to 100 line feet from the evaporator unit.
Thermostat
KDT- Advanced digital display (50-ft. cable), liquid-temperature-measuring bottle probe (50-ft. cable), 24V - Customer supplied
Temp. Delta
Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature
Warranty
Two-year limited warranty (parts and labor)
BTU/h (60°F condenser air intake
temperature)
Sensible/Total
BTU/h (75°F condenser air intake
temperature)
Sensible/Total
BTU/h (85°F condenser air intake
temperature)
Sensible/Total
4
814
/
5
687
4
455
/
4997
4370
/
4
834
H.E. Condenser (Air-Cooled
Condensing Unit)
16.1”L x 20.5"W x 15.5”H
31.18"L x 10.75”W x 21.18"H
220V (15-amp dedicated circuit required)
LRA 13.2, RLA 3.19, FLA 3.66
Cellar Size
1750 cu. ft.
*
Page 39
08/04/21