www.whisperkool.com | Page 17
Phantom Series
PREPARING THE UNIT FOR INSTALLATION
The WhisperKOOL unit requires a dedicated 115V, 20-amp circuit.
The unit draws a large amount of amps during its initial
startup. By designating a dedicated circuit breaker, you will guarantee the unit has enough power to run effectively. Contact an
electrician for assistance with the installation of this dedicated electrical circuit.
The unit must sit upright for 24 hours prior to installation.
To prepare the unit for installation:
• Remove unit from box.
• Match the electrical outlet to the plug provided on the WhisperKOOL unit.
• Provide a dedicated circuit and wiring for the unit (see above).
• Provide a weatherproof plug for units connected outside.
Power surges and spikes can damage sensitive electrical equipment. WhisperKOOL recommends plugging the unit into a surge
protector or power conditioner in order to protect your system. As outlined in our terms and conditions, power surges and spikes
are not covered under warranty.
Do not use a GFI (ground fault interrupter) with this product.
In case the unit should lose power, check the home/main circuit breaker. If the unit does not respond properly, refer to the
Troubleshooting Guide.