
24 WhisperPower Inverter / Battery Charger
Battery Charging Cycle
Charging Voltage Setting: Bulk/Absorption (AbS), Float (FLO) and Recharge (rEC)
Battery Type
Bulk Voltage
(Default)
Float Voltage
(Default)
Recharge Voltage
(Default)
GEL
13.8-14.8V
(14.2V)
13.0-14.0
(13.8V)
12.8-14.0
(12.8V)
Flooded
13.8-14.8 & 15.8V
(14.4V)
13.0-14.0
(13.5V)
12.8-14.0
(12.8V)
AGM
13.8-14.8V
(14.3V)
13.0-14.0
(13.4V)
12.8-14.0
(12.8V)
Lithium
13.8-14.8V
(13.9V)
13.0-14.0
(13.5V)
12.8-14.0
(13.2V)
Program
13.8-14.8V
(13.8V)
13.0-14.0
(13.2V)
12.8-14.0
(12.8V)
Power Supply
13.0-14.0V
(13.8V)
· Consult the battery manufacturer when choosing the bulk and float voltage for the battery bank.
· When selecting the Float voltage, it has to be with a minimum of 0.4V below Bulk Voltage setting.
· The Recharged Voltage determines the restart cycle of the battery bank. The charger will go through a
full recharge cycle when the battery voltage drops to the Recharge Voltage set value. When selecting the
Recharge Voltage, it has to be with a minimum of 0.4 below the Float Voltage setting.
· If Power Supply is chosen, the charger will provide a constant voltage to charge the battery bank.
Charging Current Setting: Bulk Stage (bUL), Absorption to Float Stage (AbS)
Model
Bulk Stage
Absorption to Float Stage
12V 3000W
100A, 80A, 60A, 40A, 25A
(Default: 100A)
20A, 15A, 10A, 5A, 2A
(Default: 10A)
12V 2000W
80A, 60A, 40A, 20A, 10A
(Default: 80A)
15A, 10A, 8A, 4A, 2A
(Default: 8A)