WhisperPower Inverter / Battery Charger
19
Unit Setting Function Chart
Unit Setting
Display
Description and Available Setting
Inverter
: Use as Inverter only. No By-Pass functions.
(Default)
: Auto Backup. Inverter automatically turns ON when AC
Blackout.
: Manual Backup. When AC Blackout occurs, Inverter has to be
manually turned ON by using the ‘Power’ button’ on either the
Display panel or the ‘Power’ button on the Main unit
: Inverter function is disabled. No AC backup when AC Blackout.
Load Sense
(Default)
: Continuous AC Output when inverter is ON
10 : Continuous AC Output when inverter is ON and AC load is > 10W
15 : Continuous AC Output when inverter is ON and AC load is > 15W
20 : Continuous AC Output when inverter is ON and AC load is > 20W
25 : Continuous AC Output when inverter is ON and AC load is > 25W
Battery Low
Disconnect
10.5
Battery Low Disconnect Voltage selectable ranges is 10.5 - 12.0V (0.1V steps)
(Default voltage is set to 10.5V
Battery Low
Warning
11.0
Battery Low Warning Voltage selectable ranges is 11.0 - 12.5V (0.1V step)
(Default voltage is set to 11.0V
Battery Low
Recovery
12.0
Battery Low Recovery Voltage selectable ranges is 11.5 - 13.0V (0.1V step)
(Default voltage is set to 12.0V
Audible
Buzzer
(Default)
: Buzzer is enabled. Unit buzzes when Warning or Error
occurs.
: Buzzer is disabled. Unit does not buzz when Warning and Error occur.
AC Charger
(Default)
: AC Charger is enabled. Charge battery when AC Input is
available.
: AC Charger is disabled. No battery charging when AC Input is available.
Battery Type
(Default)
: GEL Battery, default Bulk Charge/Float Voltage is 14.2V/13.8V
: AGM Battery, default Bulk Charge/Float Voltage is 14.3V/13.4V
: Flooded Battery, default Bulk Charge/Float Voltage is 14.4V/13.5V
: Lithium Battery, default Bulk Charge/Float Voltage is 13.9V/13.5V
: Program, default Bulk Charge/Float Voltage is 13.8V/13.2V
: Power Supply Mode, Default Power Supply Voltage 13.8V
Bulk Current
100
80
12V/3000W Models
: Selectable Ranges 100A, 80A, 60A, 40A, 25A
(Default
100A)
.
12V/2000W Models
: Selectable Ranges 80A, 60A, 40A, 20A, 10A
(Default
80A)
.
Bulk/Absorpt-
ion Voltage
14.2
Bulk/Absorption voltage is based on the battery type chosen. All battery
types have selectable ranges of 13.8 – 14.8V.
(Default on GEL Battery is
14.2V