10 WhisperPower Inverter / Battery Charger
Multi-Function Display
Typical Wiring Block Diagram of Inverter-Charger:
A
Battery Bank
•
The use of deep cycle or lithium ion battery is highly recommended for power inverter
application
•
For battery size, you need to identify how much and for how long the inverter has
to provide AC power to the loads (based on Amps x hour energy consumption). It is
recommended to purchase as much battery capacity as possible.
AC Load
Estimated run time on 12V Battery bank on 12V Input Models
12V/120AH
12V/240AH
50 W
22 hrs.
44 hrs.
100 W
11.5 hrs.
23 hrs.
200 W
5 hrs.
11 hrs.
500 W
2 hrs.
4 hrs.
1000 W
49 mins
2 hrs.
1500 W
27 mins
1 hr.
2000 W
15 mins
49 mins
2500 W
N.R.
37 mins
3000 W
N.R.
27 mins
N.R. - Not Recommended. Based on more than 2C discharged on battery capacity.
Estimated run times are for reference use only. Actual run times may vary on battery type used.