background image

15

Step G - Sanitize, Test and Purge System

SANITIZE THE SYSTEM

Sanitizing is recommended immediately after installa-

tion of the Reverse Osmosis system. It’s also recom-

mended after servicing inner parts. It is important that

the person installing or servicing the system have

clean hands while handling inner parts of the system.

Complete the following steps to sanitize the system.

See Fig. 22.

1

. Make sure that the water supply to the Reverse

Osmosis system is off.

2

. Open the Reverse Osmosis faucet. If the tank is not

already empty, allow the water to empty.

3

. Locate the eyedropper included in the parts bag and

common household bleach. 

4

. Add 3 ml. of bleach into open end of yellow tubing.

Handle bleach according to bleach manufacturer’s

recommendations. See Fig. 22.

5

. Connect yellow tubing to tank connector. See Figs.

13 and 22.

6

. Sanitizing the system will be completed during the

pressure test and purging steps on the following

page.

NOTE: The bleach must be removed from the sys-

tem before drinking the water. See purging instruc-

tions on the next page. 

FIG. 22

Manufacturer recommends using the

Model 7301203 Sanitizing Kit

To order, go to

www.whirlpoolwatersolutions.com

and click on the “Replacement Parts” link under the “Owner Center” tab,

or call toll free  

1-866-986-3223

RO

Sanitization

Cartridge

Postfilter

Sanitization

Cartridge

Prefilter

Sanitization

Cartridge

This reusable sanitizing kit (not included) is

recommended to easily and completely sani-

tize your Reverse Osmosis system annually.
The kit includes the following:

 =

Prefilter sanitization cartridge

       (contains no filtration media)

 =

Postfilter sanitization cartridge

       (contains no filtration media)

 =

RO sanitization cartridge

       (contains no RO membrane)

 =

Syringe, 1 oz.

 =

Complete instructions

Uses standard household bleach (not includ-

ed) to completely sanitize the Reverse

Osmosis system.

Summary of Contents for WHAPSRO

Page 1: ...ified by NSF International against NSF ANSI Standards 42 58 See performance data on pages 25 26 for details If you have any questions or concerns when installing operating or maintaining your reverse osmosis system call our toll free number 1 866 986 3223 or visit whirlpoolwatersolutions com When you call please be prepared to provide the model date code and serial number of your product found on ...

Page 2: ...ng 7 Step B Install Reverse Osmosis Drain 8 9 Step C Install Reverse Osmosis Filter Assembly 10 Step D Install Storage Tank 10 Step E Install Reverse Osmosis Faucet 11 12 Step F Connect Tubes 13 14 Step G Sanitize Pressure Test Purge System 15 16 How Your Reverse Osmosis System Works 17 18 Maintenance 19 20 Troubleshooting 21 Exploded View Parts List 22 23 Warranty 24 Performance Data 25 27 ...

Page 3: ...st reduction and may be used on disinfected water that may contain filterable cysts Arsenic Reduction This system shall only be used for arsenic reduction on chlorinated water supplies containing detectable residual free chlorine at the system inlet Water systems using an inline chlorinator should provide a one minute chlorine contact time before the reverse osmosis system Nitrate Nitrite Test Kit...

Page 4: ... is shipped complete in one carton Remove all items from your shipping carton Check all items against the packing list below Note any items lost or damaged in shipment Note any damage to the shipping carton Refer to the exploded view and parts list in the back of the manual for the part names and numbers of missing or dam aged items If problems exist refer to the website or the toll free number li...

Page 5: ...t Cold Water Soft Hot Water Outside Faucet Hard Water Water Heater Shutoff Valve Hard Water Line Water Softener Reverse Osmosis Drain Soft water to Reverse Osmosis System Hard Water to House Main Shutoff Valve Storage Tank Water Meter Reverse Osmosis System To Faucet Floor Drain Air Gap see p 9 FIG 4 Typical Remote Installation Additional parts required IMPORTANT Allow adequate open space behind t...

Page 6: ...d a near by water source and drain point See Fig 4 CHECK SPACE REQUIREMENTS Check size and position of items for proper installation into location chosen TOOLS NEEDED Review the tools needed list See Fig 5 Gather needed tools before proceeding with the installation Read and follow the instructions provided with any tools listed here Overview and Site Preparation OVERVIEW Read through the entire ma...

Page 7: ...ting must provide a leak tight connection to the Reverse Osmosis 1 4 tubing Locate the cold water line in the sink cabinet It is recommended but not required that the cold water line be soft water Complete the following steps to install the water supply fitting 1 Close the hot and cold water shutoff valves under the sink where the cold water supply fitting will be installed and open faucet s to re...

Page 8: ...P trap See Fig 8 Make sure that the Q C fitting is toward the direction of the RO faucet See Fig 9 NOTE Locate so that the drain tubing from the Reverse Osmosis faucet will run straight to the adaptor with no dips loops or kinks 2 Using the hole through the drain fitting as a guide mark the pipe where a 3 8 hole will be drilled See Fig 8 and remove the drain adaptor from the pipe NOTE Do not drill...

Page 9: ...the manual on how to disconnect and connect tubing NOTE A flow control insert is located inside the fitting that the drain tube connects to See No 12 on page 22 Leave this fitting in place 4 Route the tubing to the drain point and secure at the end with a bracket not included See Fig 11 Provide a 1 1 2 air gap between the end of the tube and the drain See Fig 11 Step B Install RO Drain in Remote L...

Page 10: ...Fig 13 Tighten the tubing connector onto the tank nip ple 7 8 full turns being careful not to cross thread or overtighten 3 Do not connect the tube at this time This will occur later in the assembly 4 Place the storage tank next to the Reverse Osmosis Assembly The tank can be placed upright or on its side INSTALL REVERSE OSMOSIS FILTER ASSEMBLY The Reverse Osmosis Filter Assembly can sit upright o...

Page 11: ...ATION OF REVERSE OSMOSIS FAUCET MOUNTING HOLE 3 Visually review the routing of the tubes from the Reverse Osmosis filter assembly to the faucet Check to ensure there is adequate tube routing space between the faucet and filter assembly 4 If drilling is needed drill a 1 1 4 diameter hole in the mounting surface IMPORTANT Drilling holes into countertops and sinks should only be performed by an insta...

Page 12: ...ose end of the red tube Route the red tubing from the bottom up through the faucet mounting hole Cut tube to length as needed cut ting the end square See Fig 16 Push the end of the tubing onto the 1 4 barb fitting See Fig 15 6 Work tubing and the faucet stud down into the mounting hole 7 On the underside of the sink or countertop install the spacer flat washer and hex nut Slide the large steel was...

Page 13: ...g 18 Do not stop pushing when the tube engages the o ring Failure to follow these instructions may lead to future leaks When a 1 4 tube is fully engaged 11 16 of the tube has entered the fitting When a 3 8 tube is fully engaged 3 4 of the tube has entered the fitting Mark tube with a piece of tape or marker See Figs 17 18 2 If additional tubing is required see parts list at the end of this manual ...

Page 14: ... green tube to the fitting on the water supply pipe See Fig 21 3 Cut tube square and to length See Fig 16 4 Connect to cold water supply fitting See Fig 6 5 Insert all the way into the fitting See Figs 17 18 6 Pull on the tube to be sure it is held firmly in the fitting CONNECT BLACK TUBE FROM REVERSE OSMOSIS FAUCET TO DRAIN ADAPTER 1 Locate the 3 8 black tube attached to the faucet Fig 21 2 The l...

Page 15: ...13 and 22 6 Sanitizing the system will be completed during the pressure test and purging steps on the following page NOTE The bleach must be removed from the sys tem before drinking the water See purging instruc tions on the next page FIG 22 Manufacturer recommends using the Model 7301203 Sanitizing Kit To order go to www whirlpoolwatersolutions com and click on the Replacement Parts link under th...

Page 16: ... system pressure builds slowly leaks may not be immediately appar ent Recheck for leaks 24 hours after purging the system is complete PURGING THE SYSTEM To purge the system complete the following steps 1 Open the Reverse Osmosis Faucet and let water flow through the system for a 24 hour period Water flow will be a slow trickle at this time NOTE Do not consume water from the RO sys tem until purgin...

Page 17: ...pply water pressure when the tank is full This provides fast flow to the Reverse Osmosis faucet When the tank is empty of water the pressure at the air valve is 5 7 psi Postfilter Water goes through the postfilter before going to the Reverse Osmosis faucet See Fig 24 The postfilter is an activated carbon type filter Any remaining tastes and odors are reduced from the prod uct water Clean high qual...

Page 18: ...lso reduced See Fig 24 2 Water leaves prefilter and proceeds to the Reverse Osmosis Cartridge 3 Water enters the Reverse Osmosis membrane Dissolved solids are reduced 4 Processed water leaves the Reverse Osmosis Membrane and flows to the storage tank 5 Drain water with dissolved solids leaves the Reverse Osmosis membrane and flows to the drain 6 Faucet is activated 7 Processed water leaves the sto...

Page 19: ...ace the Reverse Osmosis membrane cartridge when the production rate and or quality of product water drops Product water may begin to taste differ ent indicating solids and organics are passing through the Reverse Osmosis membrane See Reverse Osmosis membrane cartridge replacement REVERSE OSMOSIS MEMBRANE CARTRIDGE REPLACEMENT Complete the following steps to replace the cartridges 1 Remove turn to ...

Page 20: ...e collet inward until it locks in place See Figs 26 27 Change Collet and O Ring FIG 26 Collet Fitting O Ring Seal Push o ring seal into bottom of port then follow with collet Disconnect Tubing FIG 27 Tubing Collet depress to remove tubing NOTE It is not recommended that the RO assem bly be opened If this becomes necessary pay careful attention to the layout of the parts and the routing of the tubi...

Page 21: ...e to 6 psi Close faucet to refill the tank Problem High total dissolved solids TDS in product water Cause Water supply to the Reverse Osmosis sys tem not within specifications Correction Increase water pressure precondition the water etc as needed to conform before doing maintenance on the Reverse Osmosis sys tem Correction Send treated and untreated water samples to a water analysis lab for testi...

Page 22: ...22 Exploded View 19 17 16 15 14 13 1 4 red tubing 12 7 6 4 5 3 1 2 18 10 11 9 8 20 21 6 ...

Page 23: ...Nos 1 8 10 7287344 Elbow Plug in 3 8 Stem x 3 8 Tube 11 7253785 Elbow Plug in 1 4 Stem x 1 4 Tube 12 7275185 Flow Control Insert Key No Part No Description 13 WHEERF Pre Post Filter Cartridge Ù contains one of each 14 WHEERM RO Membrane Cartridge Ù 15 119 8600084 Water Supply Fitting 1 4 Q C 16 119 8600123 Drain Adaptor 17 7256018 Storage Tank 18 7251034 Connector 1 4 NPT x 3 8 Q C Tube 19 WHEFSAT...

Page 24: ...arranty Filters and membranes are not covered by the warranty TO OBTAIN WARRANTY PARTS SIMPLY CALL 1 866 986 3223 for assistance This warranty applies only while this product is in use in the United States or Canada General Provisions The above warranties are effective provided the Reverse Osmosis Water Filtration System is operated in accordance with this owner s manual including at water pressur...

Page 25: ...your water supply See elsewhere in this owner s manual for further instructions on filter replacement system installation operating procedures and warranty The maintenance instructions must be followed for the product to perform as indicated below General Information This product is an undercounter system that filters and stores quality drinking water ready for use It contains a car bon sediment f...

Page 26: ...in7 3 0 10 1 08 2 9 0 1 97 Zinc7 1 5 10 5 08 1 5 0 25 98 1 Milligrams per liter which is equivalent to parts per million PPM 2 Tested by NSF International according to NSF ANSI Standard 58 3 NSF minimum percent reduction requirement Acceptance level for this substance is based on percent reduction rather than maximum effluent concentration 4 Particles per milliliter 5 Pico Curies per liter 6 Nephe...

Page 27: ... least one minute any trivalent arsenic will be converted to pentavalent arsenic and reduced by this RO Other water treat ment chemicals such as ozone and potassium permanganate will also change trivalent arsenic to pentavalent arsenic A combined chlorine residual also called chloramine may not convert all the trivalent arsenic If you get your water from a public water utility contact the utility ...

Reviews: