10
Step C - Install RO Filter Assembly
The fitting on the supply tank may need to be tight-
ened 7-8 full turns to get a good seal.
Do not overtighten.
INSTALL STORAGE TANK
1
. Apply thread sealing tape (2 wraps clockwise) to
the threads on the nipple at the top of the tank. See
Fig 13.
2
. Locate the tubing connector (shutoff valve). See Fig.
13. Tighten the tubing connector onto the tank nip-
ple 7-8 full turns, being careful not to cross thread or
overtighten.
3
. Do not connect the tube at this time. This will occur
later in the assembly.
4
. Place the storage tank next to the Reverse Osmosis
Assembly. The tank can be placed upright or on its
side.
INSTALL REVERSE OSMOSIS FILTER
ASSEMBLY
The Reverse Osmosis Filter Assembly can sit upright
or lay on its side. See Fig. 12.
Step D - Install Storage Tank
FIG. 13
Tank
Nipple
Storage
Tank
Tubing Connector
(Shutoff Valve)
FIG. 12