2-4
DRAIN SYSTEM
The washer can be installed using the stand-
pipe drain system (floor or wall), the laundry
tub drain system or the floor drain system.
Select the drain hose installation method you
need. See “Tools and Parts,” page 2-1.
Standpipe drain system - wall or floor
(views A & B)
The standpipe drain requires a minimum
diameter standpipe of 2
˝
(5 cm). The mini-
mum carry-away capacity can be no less than
17 gal. (64 L) per minute.
The top of the standpipe must be at least 30
˝
(76.2 cm) high and no higher than 55
˝
(1.4 m)
from the bottom of the washer.
Laundry tub drain system (view C)
The laundry tub needs a minimum 20 gal.
(76 L) capacity. The top of the laundry tub must
be at least 30
˝
(76.2 cm) above the floor.
Floor drain system (view D)
The floor drain system requires a siphon break
that may be purchased separately. See “Tools
and Parts,” page 2-1.
The siphon break must be a minimum of 26
˝
(66 cm) from the bottom of the washer. Addi-
tional hoses might be needed.
30" min.
(76.2 cm)
A
B
D
C
30" min.
(76.2 cm)
26" min.
(66 cm)