Code
Failure
Meaning / Condition
F65
Dc Link Under
Voltage
Switch OFF all the loads, except IPC
power relay ,Manage Cooling fan and door
lock in accordance with specified in the
dedicated paragraph
Dc Link voltage is lower than limit for at least
30sec.
180Vrms with Load
274Vrms without load
The previous failure is cleared when a right
voltage is detected for at least 5 Mains half
cycles.