Service Competence Center
Troubleshooting
Failure Codes
In
d
uction
O
ven
Code
Failure
Meaning / Condition
F59
Coil1/2 NTC open
Switch OFF all the loads, except IPC
power relay ,Manage Cooling fan and door
lock in accordance with specified in the
dedicated paragraph
Coil NTC under 16 C for at least 30 sec.
The failure is cleared when a Temperature
greater than 16 C is detected for at least 1
seconds.