Service Competence Center
Bio Energy Step 2
A-30% ECO Forced Air Description
B
io
E
n
e
rgy
S
te
p
2
A-30% ECO Forced Air Description :
•
Cooling Fan delay: 15'
•
Eco mode always ON
•
NO pre-heating
•
Heaters period: 60s; Cavity fan period: 60s
First Phase: Ring and Grill are ON, duration 11', Cavity Fan is pulsed (30s OFF and 30s ON
without considering fan inertia)
Second Phase: Ring element is ON, duration about 60', Cavity Fan is pulsed (45/48s OFF
and 15/12s ON without considering fan inertia, depending on models)
Third Phase: Ring and Grill are ON, duration up to 720', Cavity Fan is pulsed (45/48s OFF
and 15/12s ON without considering fan inertia, depending on models)
Summary of Contents for Minerva
Page 1: ... Service Competence Center Induction Oven Minerva Platform ...
Page 22: ... Service Competence Center Operation Induction Oven Induction Functions ...
Page 23: ... Service Competence Center Operation Induction Oven Induction Functions ...
Page 24: ... Service Competence Center Operation Induction Oven Induction Functions Cooking Table ...
Page 25: ... Service Competence Center Operation Induction Oven Induction Functions Cooking Table ...
Page 26: ... Service Competence Center Operation Induction Oven Induction Functions Cooking Table ...
Page 104: ... Service Competence Center Installation Circuit Wiring Diagram Induction Oven ...
Page 112: ... Service Competence Center Documents Induction Oven I F U ...
Page 113: ... Service Competence Center Documents IFU Induction Oven Service Competence Center ...
Page 114: ... Service Competence Center Bio Energy Step 2 Minerva Platform Bio Energy Step 2 ...
Page 122: ... Service Competence Center Bio Energy Step 2 Wiring Diagram Bio Energy Step 2 Legende fehlt ...