©
Service Competence Center
Troubleshooting
Failure Codes
In
d
uction
O
ven
Code
Failure
Meaning / Condition
F58
Coil1/2 NTC
shorted
Switch OFF all the loads, except IPC
power relay ,Manage Cooling fan and door
lock in accordance with specified in the
dedicated paragraph
Coil NTC over 240 C for at least 1 sec.
The failure is cleared when a Temperature lower
than 240 C is detected for at least 1 seconds.
Summary of Contents for Minerva
Page 1: ... Service Competence Center Induction Oven Minerva Platform ...
Page 22: ... Service Competence Center Operation Induction Oven Induction Functions ...
Page 23: ... Service Competence Center Operation Induction Oven Induction Functions ...
Page 24: ... Service Competence Center Operation Induction Oven Induction Functions Cooking Table ...
Page 25: ... Service Competence Center Operation Induction Oven Induction Functions Cooking Table ...
Page 26: ... Service Competence Center Operation Induction Oven Induction Functions Cooking Table ...
Page 104: ... Service Competence Center Installation Circuit Wiring Diagram Induction Oven ...
Page 112: ... Service Competence Center Documents Induction Oven I F U ...
Page 113: ... Service Competence Center Documents IFU Induction Oven Service Competence Center ...
Page 114: ... Service Competence Center Bio Energy Step 2 Minerva Platform Bio Energy Step 2 ...
Page 122: ... Service Competence Center Bio Energy Step 2 Wiring Diagram Bio Energy Step 2 Legende fehlt ...