Vent system chart

NOTE: 

Side exhaust installations add a 90º turn inside the dryer. 

To determine maximum exhaust length, add one 90º turn to the 

chart.

Install Vent System

1.

Install exhaust hood. Use caulking compound to seal exterior 

wall opening around exhaust hood.

2.

Connect vent to exhaust hood. Vent must fit inside exhaust 

hood. Secure vent to exhaust hood with 4" (102 mm) clamp.

3.

Run vent to dryer location. Use the straightest path possible. 

See “Determine vent path” in “Plan Vent System.” Avoid 90º 

turns. Use clamps to seal all joints. Do not use duct tape, 

screws, or other fastening devices that extend into the interior 

of the vent to secure the vent, because they can catch lint.

Level Washer/Dryer

Properly leveling your washer/dryer avoids excessive noise and 

vibration.

1.

Check the levelness of the washer/dryer by placing a level 

on the top edge of the washer, first side to side, then front 

to back.

2.

If the washer/dryer is not level, prop up the front with a wood 

block and adjust the feet up or down as necessary. Remove 

wood block and lower washer/dryer. Repeat this step until the 

washer/dryer is level.

Make Gas Connection

1.

Remove the red cap from the flexible gas connector.

2.

Remove the ½" NPT adapter from the flexible gas connector 

(it will be necessary to use two adjustable wrenches).

3.

Install the adapter on the ½" rigid gas supply pipe using pipe-

joint compound.

NOTE:

 For LP gas connections, you must use pipe-joint 

compound resistant to the action of LP gas. Do not use 

TEFLON

®†

 tape.

4.

Attach the flexible gas connector to the ½" NPT adapter. 

Do not use pipe-joint compound for this connection. 
There should be a natural loop in the flexible gas connector. 

The flexible gas connector must not be twisted, kinked, or 

attached with any sharp bends.

5.

All connections must be wrench tightened.

6.

Open the shutoff valve in the supply. The valve is open when 

the handle is parallel to the gas pipe.

7.

Test all connections by brushing on an approved noncorrosive 

leak-detection solution. Bubbles will show a leak. Correct any 

leak found.

Connect Vent

1.

Using a 4" (102 mm) clamp, connect vent to exhaust outlet 

in washer/dryer. If connecting to existing vent, make sure the 

vent is clean. The vent must fit over the exhaust outlet and 

inside the exhaust hood. Make sure the vent is secured to 

exhaust hood with a 4" (102 mm) clamp.

2.

Move washer/dryer into its final location. Do not crush or kink 

vent. Make sure washer/dryer is level.

3.

Check that there are no kinks in the flexible gas line.

Number of 

90º turns 

or elbows 

Type of Vent

Box or 

Louvered 

hoods

Angled 

hoods

0

Rigid metal

43 ft (13.1 m)

36 ft (11.0 m)

1

Rigid metal

33 ft (10.1 m)

26 ft (7.9 m)

2

Rigid metal

23 ft (7.0 m)

16 ft (4.9 m)

A. ½" rigid gas supply pipe
B. Use pipe-joint compound.

C. ½" NPT adapter
D. Do not use pipe-joint compound.

E. Flexible gas connector

A. Closed valve
B. Open valve

B

A

C
D

E

†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

A

A

Summary of Contents for LTG5243DQ - 24" Twin Washer/Dryer Laundry Center

Page 1: ...ed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages T...

Page 2: ...ied or licensed by the State of Massachusetts If using a ball valve it shall be a T handle type A flexible gas connector when used must not exceed 3 feet IMPORTANT The gas installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 The dryer must be electrically grounded in accordance with local codes or in the absence of local co...

Page 3: ...t operate your washer in temperatures at or below 32ºF 0ºC Some water can remain in the washer and can cause damage in low temperatures See Washer Dryer Care in the Washer Dryer User Instructions for winterizing information Do not operate your dryer at temperatures below 45 F 7 C At lower temperatures the dryer might not shut off at the end of an automatic cycle This can result in longer drying ti...

Page 4: ...lation Kit Part Number 346764 See Tools and Parts section for information on ordering Special provisions must be made in mobile homes to introduce outside air into the dryer The opening such as a nearby window should be at least twice as large as the dryer exhaust opening DrainSystem The washer dryer can be installed using the standpipe drain system floor or wall the laundry tub drain system or th...

Page 5: ...mpany Gas supply line Must include NPT minimum plugged tapping accessible for test gauge connection immediately upstream of the gas supply connection to the dryer see illustration IPS pipe is recommended approved aluminum or copper tubing is acceptable for lengths under 20 ft 6 1 m if local codes and gas supplier permit If you are using Natural gas do not use copper tubing Lengths over 20 ft 6 1 m...

Page 6: ...into any gas vent chimney wall ceiling attic crawlspace or a concealed space of a building If using an existing vent system Clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint Replace any plastic or metal foil vent with rigid or flexible heavy metal vent Review Vent system chart Modify existing vent system if necessary to achieve the best drying perf...

Page 7: ... 1 Push legs into holes in rear corners until they snap into place 2 Check adjustability of rear legs by pushing in one leg The other leg should come out Check both legs If they do not move freely repeat Step 1 Install the front leveling legs 1 Examine the front leveling legs Find the diamond marking 2 Screw front legs by hand into the holes in the triangular braces in the front corners Use wrench...

Page 8: ... of drain hose into laundry tub or standpipe Rotate hook to eliminate kinks To keep drain water from going back into the washer Do not force excess drain hose into standpipe Hose should be secure but loose enough to provide a gap for air Do not lay excess hose on the bottom of the laundry tub For use with floor drain Do not install the drain hose form onto the corrugated drain hose You may need ad...

Page 9: ...ts and check for leaks A small amount of water might enter the washer You will drain this water later NOTE Replace inlet hoses after 5 years of use to reduce the risk of hose failure Record hose installation or replacement dates for future reference If you connect only one water hose you must cap off the remaining water inlet port Periodically inspect and replace hoses if bulges kinks cuts wear or...

Page 10: ...rt Number 4396014 29 737 mm to 50 1 27 m mismatch Special provisions for mobile home installations The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home Terminate the exhaust vent outside Determine vent path Select the route that will provide the straightest and most direct path outdoors Plan the installat...

Page 11: ...e joint compound NOTE For LP gas connections you must use pipe joint compound resistant to the action of LP gas Do not use TEFLON tape 4 Attach the flexible gas connector to the NPT adapter Do not use pipe joint compound for this connection There should be a natural loop in the flexible gas connector The flexible gas connector must not be twisted kinked or attached with any sharp bends 5 All conne...

Page 12: ...the Cycle Control knob Allow the washer to complete one whole cycle 13 To test the dryer set the dryer on a full heat cycle not an air cycle for 20 minutes and start the dryer If the dryer will not start check the following Washer dryer is plugged into a grounded 3 prong outlet Start button has been firmly pushed Electrical supply is connected Household fuses are intact and tight or circuit breake...

Reviews: