1.

Check that all parts are now installed. If there is an extra part, 

go back through the steps to see which step was skipped.

2.

Check that you have all of your tools.

3.

Dispose of/recycle all packaging materials. Keep the plastic 

foam for use if the washer/dryer should be transported.

4.

Check the washer/dryer’s final location. Be sure the vent is not 

crushed or kinked.

5.

Check that the washer/dryer is level and front leveling feet are 

tight. See “Level Washer/Dryer.”

6.

Plug into a grounded 3 prong outlet. Turn on power.

7.

Check that the water faucets are on.

8.

Check for leaks around faucets and inlet hoses.

9.

Remove the blue protective film on the console and any tape 

remaining on the washer/dryer.

10.

Read the Washer/Dryer User Instructions.

11.

Wipe the dryer drum interior thoroughly with a damp cloth to 

remove any dust.

12.

To test the washer, measure   the normal recommended 

amount of detergent and pour it into the washer. Close the lid. 

Select HEAVY DUTY and pull out the Cycle Control knob. 

Allow the washer to complete one whole cycle.

13.

To test the dryer, set the dryer on a full heat cycle (not an air 

cycle) for 20 minutes and start the dryer.

If the dryer will not start, check the following:

Washer/dryer is plugged into a grounded 3 prong outlet.
Start button has been firmly pushed.
Electrical supply is connected.
Household fuses are intact and tight, or circuit breakers 

have not tripped.
Dryer door is closed.

14.

When the dryer has been running for 5 minutes, open the 

dryer door and feel for heat. If you do not feel heat, turn off the 

dryer and check to see whether the gas supply line shutoff 

valve is open. 

If the gas supply line shutoff valve is closed, open it, then 

repeat the 5-minute test as outlined above.
If the gas supply line shutoff valve is open, contact a 

qualified technician.

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 

fire, or electrical shock.

WARNING

W10222384A

© 2008.

All rights reserved.

Benton Harbor, Michigan 49022

TM DURASAFE is a trademark of Whirlpool, U.S.A.

10/08

Printed in U.S.A.

1

2

Summary of Contents for LTG5243DQ - 24" Twin Washer/Dryer Laundry Center

Page 1: ...ed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages T...

Page 2: ...ied or licensed by the State of Massachusetts If using a ball valve it shall be a T handle type A flexible gas connector when used must not exceed 3 feet IMPORTANT The gas installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 The dryer must be electrically grounded in accordance with local codes or in the absence of local co...

Page 3: ...t operate your washer in temperatures at or below 32ºF 0ºC Some water can remain in the washer and can cause damage in low temperatures See Washer Dryer Care in the Washer Dryer User Instructions for winterizing information Do not operate your dryer at temperatures below 45 F 7 C At lower temperatures the dryer might not shut off at the end of an automatic cycle This can result in longer drying ti...

Page 4: ...lation Kit Part Number 346764 See Tools and Parts section for information on ordering Special provisions must be made in mobile homes to introduce outside air into the dryer The opening such as a nearby window should be at least twice as large as the dryer exhaust opening DrainSystem The washer dryer can be installed using the standpipe drain system floor or wall the laundry tub drain system or th...

Page 5: ...mpany Gas supply line Must include NPT minimum plugged tapping accessible for test gauge connection immediately upstream of the gas supply connection to the dryer see illustration IPS pipe is recommended approved aluminum or copper tubing is acceptable for lengths under 20 ft 6 1 m if local codes and gas supplier permit If you are using Natural gas do not use copper tubing Lengths over 20 ft 6 1 m...

Page 6: ...into any gas vent chimney wall ceiling attic crawlspace or a concealed space of a building If using an existing vent system Clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint Replace any plastic or metal foil vent with rigid or flexible heavy metal vent Review Vent system chart Modify existing vent system if necessary to achieve the best drying perf...

Page 7: ... 1 Push legs into holes in rear corners until they snap into place 2 Check adjustability of rear legs by pushing in one leg The other leg should come out Check both legs If they do not move freely repeat Step 1 Install the front leveling legs 1 Examine the front leveling legs Find the diamond marking 2 Screw front legs by hand into the holes in the triangular braces in the front corners Use wrench...

Page 8: ... of drain hose into laundry tub or standpipe Rotate hook to eliminate kinks To keep drain water from going back into the washer Do not force excess drain hose into standpipe Hose should be secure but loose enough to provide a gap for air Do not lay excess hose on the bottom of the laundry tub For use with floor drain Do not install the drain hose form onto the corrugated drain hose You may need ad...

Page 9: ...ts and check for leaks A small amount of water might enter the washer You will drain this water later NOTE Replace inlet hoses after 5 years of use to reduce the risk of hose failure Record hose installation or replacement dates for future reference If you connect only one water hose you must cap off the remaining water inlet port Periodically inspect and replace hoses if bulges kinks cuts wear or...

Page 10: ...rt Number 4396014 29 737 mm to 50 1 27 m mismatch Special provisions for mobile home installations The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home Terminate the exhaust vent outside Determine vent path Select the route that will provide the straightest and most direct path outdoors Plan the installat...

Page 11: ...e joint compound NOTE For LP gas connections you must use pipe joint compound resistant to the action of LP gas Do not use TEFLON tape 4 Attach the flexible gas connector to the NPT adapter Do not use pipe joint compound for this connection There should be a natural loop in the flexible gas connector The flexible gas connector must not be twisted kinked or attached with any sharp bends 5 All conne...

Page 12: ...the Cycle Control knob Allow the washer to complete one whole cycle 13 To test the dryer set the dryer on a full heat cycle not an air cycle for 20 minutes and start the dryer If the dryer will not start check the following Washer dryer is plugged into a grounded 3 prong outlet Start button has been firmly pushed Electrical supply is connected Household fuses are intact and tight or circuit breake...

Reviews: