PAGE 4
FOR SERVICE TECHNICIAN’S USE ONLY
DO NOT REMOVE OR DESTROY
QUICK OVERVIEW TEST MODE (Page 8)
To access Quick Overview Test Mode, perform steps 1 and 2 of
Activating the Service Diagnostic Test Modes. Toggle the cycle
selector knob until the status LEDs correspond as follows:
“Final Spin” LED On
NOTE:
Status LED names may vary between makes and models.
Press the
START
button to begin the Quick Overview test. See
page 8 for order of Quick Overview test.
Upon entering the Quick Overview test mode, the washer will
perform an automatic test with water cycles to check major
washer functions.
Pressing the
START
button will manually advance to the
next step.
Press and hold the
START
button for 3 seconds at any time
to exit any test mode.
IMPORTANT:
Lid must be closed with lid lock enabled
to perform test.
MANUAL OVERVIEW TEST MODE (Page 9)
To access Manual Overview Test Mode, perform steps 1 and 2
of Activating the Service Diagnostic Test Modes. Toggle the cycle
selector knob until the status LEDs correspond as follows:
“Final Spin & Done” LEDs On
Press the
START
button to enter Manual Overview Test Mode.
See page 9 for Manual Overview Test Mode.
Upon entering the Manual Overview test mode, the washer
will have all outputs OFF.
The cycle selector knob is used to select the output
to be tested.
The
START
button will activate/deactivate the selected output.
When the selected output is activated, the corresponding
status LEDs flash ON & OFF.
Press and hold the
START
button for 3 seconds at any time
to exit any test mode.
IMPORTANT:
As a safety feature, the lid must be closed
with lid lock enabled to activate either Agitate or Spin Test.
NOTE:
Multiple outputs may be activated simultaneously.
NOTE:
Outputs left on will time-out after 5 minutes.
CALIBRATION MODE
IMPORTANT:
Calibration must be performed when any of
the following components have been replaced: Main Control,
Basket, Drive Assembly, Suspension, Motor, and Capacitor.
Calibration should also be performed when the washer is moved
to a different location or, more specifically, to a different power
outlet. Not performing calibration may result in poor wash
performance.
To access Calibration Mode, perform steps 1 and 2 of Activating
the Service Diagnostic Test Modes. Toggle the cycle selector
knob until the status LEDs correspond as follows:
“Rinse” LED On
NOTE:
Status LED names may vary between makes and models.
Press the
START
button to begin washer calibration. All status
LEDs will turn on.
Do
NOT
interrupt calibration, disturb washer, or remove
power; otherwise, calibration must be repeated.
Lid must be down to perform test.
Basket must be empty to perform test (no water or clothes).
Calibration cycle runs for approximately 2–4 minutes.
Cycle completes when door unlocks and washer enters
standby mode.
UI TEST MODE
To access UI (User Interface) Test Mode, perform steps 1 and 2
of Activating the Service Diagnostic Test Modes. Toggle the cycle
selector knob until the status LEDs correspond as follows:
“Rinse & Final Spin” LEDs On
NOTE:
Status LED names may vary between makes and
models. Use LED # identifications.
Press the
START
button to begin the UI test.
Upon entering the UI test mode, all status LEDs will be
turned ON.
Pressing the
START
button will turn on and off all status
LEDs, or toggle the state of each status LED independently.
(Example: if 2 are on, and 3 are off, then 2 will be turned off
and 3 turned on.)
When toggling the cycle selector knob, each double click
will toggle the “Done” (5) LED.
Turning the rotary switch will toggle the following status LED
on and off.
t 4FOTJOH-PBE-&%
Press and hold the
START
button for 3 seconds.
Washer will exit UI test mode after 5 minutes of inactivity
or unplugging the power cord.
Sensing Soak/
Final
Load
Wash
Rinse
Spin
Done
Sensing Soak/
Final
Load
Wash
Rinse
Spin
Done
Sensing Soak/
Final
Load
Wash
Rinse
Spin
Done
(1)Sensing (2)Soak/
(4)Final
Load
Wash (3)Rinse Spin
(5)Done