59
Section Two - Part C
TROUBLESHOOTING AND DIAGNOSTICS
POSSIBLE CAUSE/TEST
PROBLEM
WON'T POWER UP
1.
Unplug unit for more than 5 seconds, then plug back in.
(Verify lid is closed)
2.
Check 120V at outlet.
3.
Check harness connections.
4.
Check 120V between 9-pin connector and ground.
WON’T START
1.
Verify unit is not in Pause or Service Mode.
(Verify lid is closed)
2.
Unplug unit for 5 seconds, then plug back in.
3.
Verify power between 9-pin connector and ground.
CONTROL LOOPS THROUGH
1.
Unit is in Service Mode. Unplug for more than
CYCLE REPEATEDLY
5 seconds, then plug back in.
WON’T FILL
1.
Check installation. Verify water supply. Verify valves are
(Verify lid is closed)
turned on.
2.
Check screens on water valve.
3.
Operate Actuator and Switch test.
4.
Check resistance measurements with unplugged unit.
5.
Check connections on water valves.
6.
Verify 120V at valves during fill. If no voltage exists and
above solutions fail, replace electronic control.
OVERFILLS
1.
Check Water Level switch hose connections.
2.
Check Water Level switch using ohmmeter.
3.
Blow into Water Level switch hose to tub to dislodge lint in
air dome.
4.
Do not adjust Water Level switch. Adjusting Water Level
switch will cause flooding.
5.
Check connections on Water Level switch.
6.
If machine still overfills replace Water Level switch.
7.
If above solutions fail, replace electronic control.
WON’T AGITATE OR AGITATOR
1.
Perform Actuator and Switch Test for Dry Agitate.
ROTATES IN ONE DIRECTION
2.
Verify 120V between the control yellow wire (counterclock-
(Verify lid is closed)
wise) and ground and between the red wire (clockwise)
and ground. Verify power at the motor.
If the voltage is at the motor and the unit does not agitate
replace motor.
If no voltage comes from the control replace the electronic
control.
NOTE: The voltage pulsates; it does not stay on. It is diffi
cult to check with a Digital Volt Meter.
WRONG AGITATE SPEED
1.
Check belt tension. There should be light deflection
(approximately 1/8") when pressed. (Loose belt will also
cause black mark on inside of cabinet.)
TROUBLESHOOTING
NOTE: Check the Tech Sheet provided with the washer form the most recent troubleshooting
information.
IMPORTANT: Possible Cause/Test MUST be performed in the sequence shown for each problem.
Summary of Contents for APARTMENT MAINTENANCE SERIES
Page 16: ...8 AGITATION Fig 2 8 Water Level Switch Timer Pump Drive Motor Gearcase ...
Page 18: ...10 DRAIN Fig 2 12 Water Level Switch Timer Pump Drive Motor Gearcase ...
Page 20: ...12 SPIN Fig 2 15 Water Level Switch Timer Clutch Spin Gearcase Drive Motor Pump ...
Page 22: ...14 NOTES ...
Page 40: ...32 WIRING DIAGRAM Typical ...
Page 41: ...33 CYCLE CHART Typical CAM SW ...
Page 44: ...36 NOTES ...
Page 45: ...37 22 COMPACT WASHER ...
Page 46: ...38 ...
Page 66: ...58 NOTES ...
Page 73: ...65 Section Two Part D TECHTIPS WIRING DIAGRAM ...
Page 75: ...67 STRIP CIRCUITS FILL AGITATE ...
Page 76: ...68 STRIP CIRCUITS SPIN DRAIN ...
Page 77: ...69 29 AND COMPACT GASANDELECTRIC DRYERS ...
Page 78: ...70 ...
Page 86: ...78 NOTES ...
Page 87: ...79 27 GASANDELECTRIC DRYERS ...
Page 88: ...80 ...
Page 102: ...94 NOTES ...
Page 105: ...97 WIRING DIAGRAM Electric Dryer Section Four Part D TECHTIPS ...
Page 106: ...98 WIRING DIAGRAM Gas Dryer ...
Page 111: ...103 27 THIN TWIN ...
Page 112: ...104 ...
Page 126: ...118 NOTES ...
Page 131: ...IX ...
Page 132: ...X CORPORATION ...