15
NOTE:
• The appliance must be installed in accordance with national wiring regulations.
• The appliance must not be installed in a laundry area.
• The appliance must be installed at a height of 2.3m above the floor.
• The appliance must be positioned so that the plug is accessible.
• For selected models with a cooling capacity above 4600W (17000BTU/h), an all-pole disconnect switch
with contact gap of at least 3mm must be fitted in the fixed wiring in accordance with national
regulations.
Installation of the drain hose
NOTE:
• The drain hose must be positioned beneath the
copper pipe.
• The drain hose must not be kinked or twisted.
• While insulating the drain hose, do not pull it.
• The section of the drain hose that passes through
the wall must be thermally insulated.
• The copper pipe and the drain hose must be lagged
using felt strip. Adiabatic pads must be used where
the pipe passes through the wall.
ROUTE OF PIPE
If the pipe comes out on the right side of the indoor
unit, cut part "1" of the unit.
If pipe comes out on the lower-right side of the indoor
unit, cut part "2" of the unit.
If pipe comes out on the left side of the indoor unit,
cut part 3 of the unit.
REPOSITIONING THE DRAIN HOSE
If the pipe comes out on the left side of the indoor
unit, the drain hose must be repositioned, otherwise
water may leak from the unit.
Repositioning procedure: Invert the position of drain
hose and drain rubber plug.
Clearance is not allowed after repositioning, as it
would result in leaking.
Installation of the indoor unit
Pass the pipe through the hole in the wall and attach
the indoor unit to the mounting plate (press the tab on
the indoor unit into the hook on the mounting plate.)
Liquid pipe
gas pipe
Adiabatic
underlay
Drain hose
felt
drain hose
Drain rubber plug
Indoor unit
the mounting
plate
Bottom
the tab of
indoor unit