13
Attention:
The allowable length of the connecting pipe is
10m.
The allowable distance between indoor unit and
outdoor unit is 5m.
Confirm the installation position using the marks
on the indoor mounting plate.
Note: Different models have different
mounting plates, the installing charts of this
book are presented just for the purpose of
illustration, please take the real objects as
reference.
The copper pipe can be installed to the back, right,
underside, or left-back side.
Notice: do not raise the drain hose.
While installing the pipeline on thin armor plate or
wire mesh wall, use a wooden board to clamp
between the wall and the pipeline, or wrap the
pipeline with 7-8 layers of insulating plastic tape.
Cover the connecting pipe with adiabatic material.
NOTICE D’INSTALLATION
above 105mm
back
right
back
underside
left-back
left
front
8mm thick sponge plastic
adiabatic material.
PP
ҹϞ
above 155mm
above 250mm
above 20mm
above 500mm
above 300mm
above 500mm
above 500mm
above 300mm