3.4. REGULATION
VIEWING THE SET TEMPERATURE (Set Point)
To view the set temperature simply press the “
SET
” key and release it.
ALTERING THE SET TEMPERATURE (Set Point)
Hold down the “
SET
” key for 2 seconds. With the LED
flashing, press the
and
keys to set the temperature given on the display (within a range of 0÷14°C)
ALTERING THE VALUE OF A PARAMETER (alteration of the set differential -
hysteresis)
Press the “
SET
” and
keys simultaneously for a few seconds (the LEDs
and
start flashing) until the initials HY appear on the display.
Press the “
SET
” key to access the hysteresis value and alter it (within a range of 0.1 ÷
25.5°C) by means of the
and
keys until the required value is reached.
Press the “
SET
” key again to confirm the new value, then wait 15 seconds (without
pressing any keys).
ATTENTION !
WITH THE EXCEPTION OF VALUES FOR THE “SET” PARAMETER, ALL
OTHER VALUES ARE SET IN ORDER TO ACHIEVE THE SPECIAL
FUNCTIONS FOR WHICH THE APPLIANCE IS DESIGNED.
CONSEQUENTLY ANY TAMPERING WITH THE CONTROLS EXONERATES
THE MANUFACTURER FROM ANY COMMITMENT OR RESPONSIBILITY
WHATSOEVER.