___________________________________________________________________________
Infrastructure Installation Guide
___________________________________________________________________________ 28
Location Sensor Installation Guide
D0405 rev PA6
Copyright WhereNet, Corp. 2001
WhereNet Confidential
q
Location Sensor mounted /-1 foot (0.3 m) of position specified in
Site Design document. After measuring the installed position,
documenting it on the following form, and comparing it to the position
specified in the Site Design document, the Account Manager should place
an “X” in the installed position accepted/rejected line for each Location
Sensor on site.
q
MAC and IP addresses recorded in document below. One or more MAC
label(s) placed on the Location Sensor in a position visible from ground.
q
Location Sensor mounted properly with cylindrical antennas pointing down
a minimum of 12” (0.3 m) from metal walls.
q
Ethernet, power, timing (if required), and antennas cables properly
connected.
LS Site
Design ID
Number
Reference
point desc.
(e.g., column
E12)
Distance and
bearing from
reference point
in X direction
Distance and
bearing from
reference point
in Y direction
Height above
floor level Z/
Direction LEDs
are facing
1.
MAC address:
IP address:
Specified in
Site Design
Actual
installed