Confirm that the site LS channel assignment is correct by running “display
locate” from the LP Manager tool with a tag placed directly under each LS.
Verify that the nearest LS, as indicated by a “0” in the display locate
report, is that LS nearest the tag.
q
Verify that detects are received on the channel by using either LP Manager
Detect History, or WT LPHealth APC detects when a tag is placed at a
distance from each LA equivalent to the maximum required range from
that LA. Typical tag to LA range is 1000 ft (305 m) (Unobstructed/
outdoor), 350 ft (107 m) Minimally Obstructed (indoor office/ light
commercial), 250 feet (76 m) Significantly Obstructed (heavy industrial).
Section Signoff
Initial
Date
Comments/ Exceptions