page 5 – 4
D-8000 / Jan 2003
C O N T R O L R O O M M O D U L E
Hook-Ups
As stated before, all user wiring to and from the CRD-8 module takes
place at two DB-25 multi-pin connectors mounted directly beneath the
module on the console mainframe’s bottom pan.
Upper DB-25 Connector — Audio
Includes cue, headphone and control room outputs. All audio signals
are +4dBu balanced, analog stereo.
Pin 25 – Cue Lt Out SH
Pin 24 – Cue Lt Out HI
Pin 12 – Cue Lt Out LO
Pin 11 – Cue Rt Out SH
Pin 10 – Cue Rt Out HI
Pin 23 – Cue Rt Out LO
Pin 22 – Hdpn Lt Out SH
Pin 21 – Hdpn Lt Out HI
Pin 9 – Hdpn Lt Out LO
Pin 8 – Hdpn Rt Out SH
Pin 7 – Hdpn Rt Out HI
Pin 20 – Hdpn Rt Out LO
Pin 19 – CR Lt Out SH
Pin 18 – CR Lt Out HI
Pin 6 – CR Lt Out LO
Pin 5 – CR Rt Out SH
Pin 4 – CR Rt Out HI
Pin 17 – CR Rt Out LO
Upper DB-25 Connector — Control
The console’s on-air tally port is on the CRD-8 upper DB-25
connector. This is a simple relay closure that activates whenever
programmed input modules are turned ON. The port can be used to
control an externally powered tally light that requires a continuous
closure to function.
Pin 14 – On-Air Tally Relay COM
Pin 1 – On-Air Tally Relay N.O.
!
Typical DB-25
connector
See pinout drawing on
page 5-6 for all wiring con-
nections at a glance.
Maximum current through
the on-air tally relay clo-
sure is 2 amps @30VDC.
Summary of Contents for D-8000
Page 148: ...D 8000 Oct 2002 page 17 14...
Page 149: ...D 8000 Oct 2002 page 17 15...
Page 152: ...page 17 18 D 8000 Oct 2002...
Page 153: ...D 8000 Oct 2002 page 17 19...
Page 154: ...page 17 20 D 8000 Oct 2002...
Page 155: ...page 17 21 D 8000 Oct 2002...
Page 156: ...page 17 22 D 8000 Oct 2002...
Page 157: ...page 17 23 D 8000 Oct 2002...
Page 158: ...D 8000 Oct 2002 page 17 24...
Page 161: ...page 17 27 D 8000 Oct 2002...
Page 165: ...page 17 31 D 8000 Oct 2002...
Page 166: ...page 17 32 D 8000 Oct 2002...