page 15 – 3
D-8000 / Jan 2003
R O U T E R C O N T R O L L E R M O D U L E
Internal Programming Options
• XY-4/8 Module
There are three four-position user-programmable dipswitches (SW1,
SW2, SW3) and two slide switches (SW4, SW5), located on the module’s
PCB.
For the purposes of this manual, we will assume you are holding the re-
moved module upright, component side towards you, with gold-plated card
fingers to the left and the module faceplate to the right. This will enable you to
read the control legends silkscreened next to each programming switch. Note
when a dipswitch position is thrown to the right (towards the module’s face-
plate) it is ON.
• XYD-600 Meterbridge-Mounted Controller
There are two four-position user-programmable dipswitches (SW1,
SW2), two slide switches (SW3, SW4), and two jumpers J2 and J3 located
on the XYC-600 PCB. These components all appear on the side of the
XYC-600 PCB that is visible when you open the meterbridge.
XY Controller Settings
Setting an XY Controller Termination—Only set termination on the
last XY controller in the chain.
• XY-4/8 Module
Four-position dipswitch SW3 located on the XYC-700 PCB is used for
XY Controller termination. To set termination active simply turn on
positions 2, 3 and 4 of dipswitch SW3 (pos1 - not used).
• XYD-600 Meterbridge-Mounted Controller
To set termination active install jumpers J2 and J3 on the XYC-600 pc
board.
Setting an XY Controller Address
The XY controller has a unique address from 1 to 64 that identifies its
presence to the system. This address is set via a pair of four position
dipswitches, SW1 and SW2, mounted on the controller’s XYC-700 PCB
for the XY-4/8 or XYC-600 PCB for XYD-600. XY controller addresses
are binary coded with each dipswitch carrying a specific numerical weight
(e.g. 1, 2, 4, 8, 16, 32). To set an address, simply turn ON the address
dipswitches until the total weights add up to the desired decimal address.
You can verify the address setting by watching for the address number in
the controller’s displays. Addressing is set at the factory and generally will
not need to be changed in the field. Below are the tables of switch positions
and their weights.
Summary of Contents for D-8000
Page 148: ...D 8000 Oct 2002 page 17 14...
Page 149: ...D 8000 Oct 2002 page 17 15...
Page 152: ...page 17 18 D 8000 Oct 2002...
Page 153: ...D 8000 Oct 2002 page 17 19...
Page 154: ...page 17 20 D 8000 Oct 2002...
Page 155: ...page 17 21 D 8000 Oct 2002...
Page 156: ...page 17 22 D 8000 Oct 2002...
Page 157: ...page 17 23 D 8000 Oct 2002...
Page 158: ...D 8000 Oct 2002 page 17 24...
Page 161: ...page 17 27 D 8000 Oct 2002...
Page 165: ...page 17 31 D 8000 Oct 2002...
Page 166: ...page 17 32 D 8000 Oct 2002...