page 15 – 5
D-8000 / Jan 2003
R O U T E R C O N T R O L L E R M O D U L E
Cable Wiring
Cables used for connecting a 2001 Router RS-485 serial port to the
console’s XY Controller are a high quality dual twisted pair cable
suitable for extended distance data transmission. A cable with an
impedance of 125 ohms and nominal capacitance of 12.8 pF/ft @1
MHz is recommended. See cable specifications and pinouts for details.
Typical RS-485 Cable Specifications
Conductors 4 conductor plus shield (2 twisted pairs)
Conductor Gauge 24 AWG (7 x 32 AWG) TC
Nom. Capacitance 12.8 pF/ft
41.9 pF/m
@ 1 MHz
Impedance 125 ohms, Nominal
Console RS-485 Cable Pinouts
• XY-4/8 Module
• XYD-600 Meterbridge-Mounted Controller
1
6
3
8
TX +
TX -
RX +
RX -
PIN
8
21
1
14
PIN
Connector Type
DB-9
Male
Connector Type
Upper/Lower
DB-25
Male
Pair 1
Pair 2
Pair 1
Pair 2
2001 Router
CPU (OAN) End
Console End
XY-4/8 module
1
6
3
8
TX +
TX -
RX +
RX -
PIN
1
6
3
8
PIN
Connector Type
DB-9
Male
Connector Type
Upper/Lower
DB-9
Male
Pair 1
Pair 2
Pair 1
Pair 2
2001 Router
CPU (OAN) End
Console End
XYD-600
Summary of Contents for D-8000
Page 148: ...D 8000 Oct 2002 page 17 14...
Page 149: ...D 8000 Oct 2002 page 17 15...
Page 152: ...page 17 18 D 8000 Oct 2002...
Page 153: ...D 8000 Oct 2002 page 17 19...
Page 154: ...page 17 20 D 8000 Oct 2002...
Page 155: ...page 17 21 D 8000 Oct 2002...
Page 156: ...page 17 22 D 8000 Oct 2002...
Page 157: ...page 17 23 D 8000 Oct 2002...
Page 158: ...D 8000 Oct 2002 page 17 24...
Page 161: ...page 17 27 D 8000 Oct 2002...
Page 165: ...page 17 31 D 8000 Oct 2002...
Page 166: ...page 17 32 D 8000 Oct 2002...