4000x Series Digital Clock 

Operating and Installation Instructions

 

6 - Network Setup 

The 4000N and 4000NE series digital clocks are fi ed with a 10/100Base-T Ethernet network interface and 

designed to synchronise to a remote NTP (Network Time Protocol)  me server across a TCP/IP computer 

network.   
Upon ini al installa on, the unit IP address, subnet mask, gateway and NTP  me server IP address shall be 

automa cally assigned by a DHCP server (if available).  Alterna vely, the unit IP address, subnet mask, 

gateway and NTP  me server IP address can be sta cally assigned. 
The table below details the available network parameters.  Please contact your network administrator for 

details of network configura on & addresses that will allow the clocks to be used on your network. 
 

Fu Nt 

Network settings 

Function 

Display Type 

Description 

'Up' button 

function 

 

hh:mm 

(4200) 

hh:mm:ss 

(4010) 

 

 

DHCP Setting 

dh  Fu 

dh  Full 

Full DHCP mode. Automa c assignment of IP, Subnet and 

Gateway by customers DHCP server. Automa c 

assignment of NTP servers via DHCP op on 42. 

Exit to Time 

display 

 

dh  Ye 

dh  Yes 

DHCP mode. Automa c assignment of IP, Subnet and 

Gateway by customers DHCP server. User se ng of NTP 

server addresses. 

Exit to Time 

display 

 

dh  No 

dh  No 

Sta c assignment of IP, Subnet and Gateway addresses 

by user. User se ng of NTP server addresses. 

Select IP Byte 1 

IP Byte 1 

I  010 

I  010 

IP Address se ng 1st Byte / Octet 
Range 0 - 254 

Select IP Byte 2 

IP Byte 2 

I  001 

I  001 

IP Address se ng 2nd Byte / Octet 
Range 0 - 255 

Select IP Byte 3 

IP Byte 3 

I  000 

I  000 

IP Address se ng 3rd Byte / Octet 
Range 0 - 255 

Select IP Byte 4 

IP Byte 4 

I  100 

I  100 

IP Address se ng 4th Byte / Octet 
Range 0 - 255 

Select Subnet 

Byte 1 

Subnet 

Byte 1 

S  255 

S  255 

Subnet Address se ng 1st Byte / Octet 
Range 0 - 255 

Select Subnet 

Byte 2 

Subnet  

Byte 2 

S  255 

S  255 

Subnet Address se ng 2nd Byte / Octet 
Range 0 - 255 

Select Subnet 

Byte 3 

Subnet  

Byte 3 

S  000 

S  000 

Subnet Address se ng 3rd Byte / Octet 
Range 0 - 255 

Select Subnet 

Byte 4 

Subnet  

Byte 4 

S  000 

 000 

Subnet Address se ng 1st Byte / Octet 
Range 0 - 255 

Select Gateway 

Byte 1 

Gateway 

Byte 1 

G  010 

G  010 

Gateway Address se ng 1st Byte / Octet 
Range 0 - 254 

Select Gateway 

Byte 2 

Gateway 

Byte 2 

G  001 

G  001 

Gateway Address se ng 2nd Byte / Octet 
Range 0 - 2555 

Select Gateway 

Byte 3 

Gateway 

Byte 3 

G  000 

 000 

Gateway Address se ng 3rd Byte / Octet 
Range 0 - 255 

Select Gateway 

Byte 4 

Gateway 

Byte 4 

G  001 

G  001 

Gateway Address se ng 1st Byte / Octet 
Range 0 - 255 

Exit to Time 

display 

 

 

9

 Issue 2.2 

Summary of Contents for 4000x Series

Page 1: ...hronisa on Setup Page 9 7 Network Setup Page 12 8a Display Setup 4200x and 4010x series Page 13 8b Calendar Setup 4500x and 4600x series Page 14 9 Stopwatch Setup Page 15 10 External Interface Setup P...

Page 2: ...the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protec on against harmful interference in a residen al installa on The equ...

Page 3: ...sor All of the digital clocks also have the ability to operate as a mul range programmable stopwatch using supplied infrared remote control or for 4000NE and 4000E units only using an external stopwat...

Page 4: ...ould be easily accessible All installa on work should be performed in accordance with current Building Regula ons and the Seventeenth Edi on of the IEE Wiring Regula ons or equivalent local standard T...

Page 5: ...t se ng Func on Loca on Se ng Mode See page 5 1 Press Up to enter Loca on Se ng Mode or press to move to next se ng Func on Synchronisa on Se ng Mode See page 6 1 Press Up to enter Synchronisa on Se n...

Page 6: ...Up to set minutes count Minutes Se ng Mode Press or to increment or decrement minutes Press Up to set the hours count Complete me se ng process detailed in table below Fu Ti Time and Date settings Fu...

Page 7: ...ST MEZ MESZ Brussels Frankfurt 1 Yes 04 UTC 2 BRAVO SAST Jo burg Pretoria S Africa 2 No 05 EET EEST Greece Athens Ukraine Kiev 2 Yes 06 IST IDT Israel Tel Aviv 2 Yes 07 MSK 1 Russia Kaliningrad 3 No 0...

Page 8: ...n na Buenos Aires 3 No 63 BRT BRST Brazil Brasilia Sao Paulo 3 Yes 64 WGT WGST Greenland West Nuuk 3 Yes 65 PMST PMDT US Pierre Miquelon 3 Yes 66 UYT UYST Uruguay Montevideo 3 Yes 67 UTC 2 5 2 1 2 No...

Page 9: ...s DHCP server User se ng of NTP server addresses Exit to Time display dh No dh No Sta c assignment of IP Subnet and Gateway addresses by user User se ng of NTP server addresses Select IP Byte 1 IP Byt...

Page 10: ...2 Time code from exis ng 5200 4860 or 482D series master clock Y Y Y Zo 1 F w482 me code zone that unit will use for synchronisa on DCF DCF77 Radio me code synchronisa on requires 484 03 radio receive...

Page 11: ...d the Up arrow should be pressed again to return to the me display If clock is to DHCP or Sta c modes the 4 bytes of the rst NTP me server address can be programmed in same manner as detailed for the...

Page 12: ...to DCF or MSF radio me code when connected to either the 484 02 MSF Radio Receiver or 484 03 DCF Radio Receiver supplied separately as follows Clock configuration 1 Press Menu or Up bu on to access c...

Page 13: ...me date and con nuous date in a number of di erent display formats as detailed in the table below Fu Di Display Setup Function Display Type Description Up button function hh mm 4200 hh mm ss 4010 Disp...

Page 14: ...language table below Calendar 2 Mode Calendar 2 Mode M2 xx As mode se ngs for Calendar 1 above Calendar 2 Lang Calendar 2 Language C2 xx Calendar 2 Language as per language table below Calendar 3 Mod...

Page 15: ...ect hold mode SA 03 SA 03 Down from pre programmed start me then up from zero Select hold mode SA 04 SA 04 Down from pre programmed start me automa cally restart countdown Select hold mode Hold Mode S...

Page 16: ...n provide synchronisa on to a maximum 5 4000E units See Local Master documenta on for further details Exit to me display 11 System setup The system setup menu contains general setup op ons for the 400...

Reviews: