background image

Declaration no.: EU-753.133-000

We the undersigned:

Name of manufacturer: 

Munster Simms Engineering Ltd

Address: 

277 – 279 Old Belfast Road, Bangor, BT19 1LT

Country: 

Northern Ireland

Declare under our sole responsibility that the following apparatus:

Product description: 

Pump controller

Model name and no.: 

Watermaster® IC EP1632

Brand name: 

Whale

Is in conformity with the following relevant EU Legislation:

EMC directive 2004/108/EC

LVD directive 2006/95/EC

Based on the following harmonized standards:

EN55014-1:2000 

EMC Emissions

EN55014-2:1997 

EMC Immunity

And therefore complies with the essential requirements of those directives.

Additional information:

Technical file number: 

TF-753.133-000

Location of technical file: 

Munster Simms Engineering Ltd, 277-279 Old Belfast Road , Belfast, BT19 1LT

Year mark first applied: 

2012

Limitations of use: 

For use with EP1612 12V submersible pump only

Name and position of person binding the manufacturer or authorized representative:

Signature:

Name: Stanley McFarland

Function: Engineering Director

Location: 

Munster Simms Engineering Ltd

277 – 279 Old Belfast Road, Northern Ireland, BT19 1LT

Date of Issue: 

27.03.12

CE marked

Watermaster® IC is protected by the following pending Patent Application

Patent UK patent application no. 1017025.6

WHALE® and Watermaster® are registered trademarks of Munster Simms Engineering Limited, Bangor, Northern

Ireland trading as Whale®. WHALE IC™ and IC Intelligent Control™ logo device are trademarks pending registration

of Munster Simms Engineering Limited, Bangor, Northern Ireland trading as Whale®.

8

14. 

PATENTS AND TRADEMARKS

13. 

EU DECLARATION OF CONFORMITY, STANDARDS & APPROVALS

Summary of Contents for EP1632

Page 1: ...uct is designed for use with freshwater If it is intended for use with any other liquid it is the user s responsibility to ensure that the materials are fully compatible with the liquids to be used and that a system of safe working practice is applied to installation use and maintenance SPECIFICATION High Flow Watermaster Pump with Intelligent Control IC EP1632 INSTALLATION USER INSTRUCTIONS Produ...

Page 2: ...at low battery voltages and in a run dry situation when the water supply runs out This patent applied for Intelligent Control is achieved by a pressure switch turning on the pump when the pressure drops to a low level and the microprocessor turning off the pump at programmed current levels which are set during the one time calibration process This calibration process may have to be repeated if the...

Page 3: ...ons Fire hazard Wiring must comply with applicable electrical standards and include a properly sized fuse or circuit breaker Improper wiring can cause a fire resulting in injury or death Suggested wiring information is given as a guide only Please note that incorrect installation may invalidate the warranty The Watermaster IC is designed to work in conjunction with a 5 Amp automotive fuse see fuse...

Page 4: ...t TO CONNECT THE IC CONTROL UNIT BACK OF SOCKET Step 1 Switch off the 12V d c supply at the main panel isolator switch Step 2 Unplug the spade connections on the water inlet socket ensuring that you note the order of wires for reconnection with the Watermaster IC see Fig 1 Fig 2 Step 3 Unscrew and remove the pressure switch adjusting screw and locking nut see Fig 2 Step 4 Remove securing screw see...

Page 5: ...expelled turn off tap the pump should turn off after approximately 10 seconds TO CALIBRATE THE SYSTEM Step 1 Press and hold the calibration button until the green LED starts to flash after 1 3 seconds Fig 7 Step 2 Open the tap and the pump should start there maybe a short delay Step 3 After approximately 30 seconds turn off the tap Step 4 After approximately 10 seconds the pump should still be run...

Page 6: ... as per steps above in Section 6 To obtain efficient running and maximum pump life ensure the following There is sufficient water in the container Maximum pumping period is not more than 15 minutes All hose connections are firm and water tight The power supply is adequate low performance could result from a weak battery or reduced voltage due to undersized wiring we recommend wiring should be a mi...

Page 7: ...connections in pipework Recalibrate the system Diagnostic Codes To aid with troubleshooting the LED on the back of the Watermaster IC has a number of different flash codes as described in the table below Watermaster IC does not require any additional winterizing For details of how to drain your water system for winterizing please visit www whalepumps com rv For installation or serviceable parts ad...

Page 8: ...ster Simms Engineering Ltd 277 279 Old Belfast Road Belfast BT19 1LT Year mark first applied 2012 Limitations of use For use with EP1612 12V submersible pump only Name and position of person binding the manufacturer or authorized representative Signature Name Stanley McFarland Function Engineering Director Location Munster Simms Engineering Ltd 277 279 Old Belfast Road Northern Ireland BT19 1LT Da...

Page 9: ...ecifications without prior notice Illustrations are for guidance purposes only Please note that by contacting Whale Support you will be indicating your consent to receiving product updates recall information help guides and appropriate marketing messages from us via post email or telephone unless you indicated an objection to receiving such messages Munster Simms Engineering Ltd Old Belfast Road B...

Reviews: