CONTENTS

1. 

Principles of Operation

2. 

Application

3. 

Warnings

4. 

Parts List

5. 

Optional Extras

6.

Installation

7. 

Instructions for Use

8.

Maintenance

9.

Helpful Hints

10. 

Trouble Shooting

11. 

Winterising

12. 

Service Support Details

13. 

EU Declaration of Conformity, Standards & Approvals

14. 

Patents and Trademarks

15. 

Warranty Statement

LIST OF IMAGES

Fig. 1

Watermaster® IC Features

Fig. 2

Wiring Connections Watermaster® Socket

Fig. 3 

Preparing Watermaster® Socket For Connecting Watermaster® IC

Fig. 4     

Place Securing Screw Into Watermaster® IC

Fig. 5     

Insert Screw Into Watermaster® IC

Fig. 6     

Installing The System

Fig. 7     

Calibrating The System

Fig. 8   

Storing Pump Plug Kit

The Watermaster® IC is a means of control for the Whale® Watermaster® High Flow system, which allows it to 

operate without the need for pressure switch adjustment. It offers three key features, eliminates rapid water pulsation,

ensures that the pump turns off at low battery voltages and in a run-dry situation when the water supply runs out. 

This (patent applied for), Intelligent Control is achieved by a pressure switch turning on the pump when the pressure

drops to a low level and the microprocessor turning off the pump at programmed current levels, which are set during

the “one time” calibration process. This calibration process may have to be repeated if the pump is replaced. 

Additionally “soft” start/stop control is used to control the pump motor.

To the Fitter:

Check that the product is suitable for the intended application, follow these installation instructions and ensure all 

relevant personnel read the points listed below. Also ensure that these operating instructions are passed on to the

end user.

To the User:

Please read the following carefully before installation

• 

Removes the need for adjustment of the pressure switch, and removes the requirement to have a surge 

damper or inline pressure switch in the system.

• 

Watermaster® IC is pre-programmed and must initially be calibrated before use - see Section 6.

When the system has shut down due to running out of water, reset by turning the pump isolation switch off 

and back on after refilling the tank.

2

1. 

PRINCIPLES OF OPERATION

Summary of Contents for EP1632

Page 1: ...uct is designed for use with freshwater If it is intended for use with any other liquid it is the user s responsibility to ensure that the materials are fully compatible with the liquids to be used and that a system of safe working practice is applied to installation use and maintenance SPECIFICATION High Flow Watermaster Pump with Intelligent Control IC EP1632 INSTALLATION USER INSTRUCTIONS Produ...

Page 2: ...at low battery voltages and in a run dry situation when the water supply runs out This patent applied for Intelligent Control is achieved by a pressure switch turning on the pump when the pressure drops to a low level and the microprocessor turning off the pump at programmed current levels which are set during the one time calibration process This calibration process may have to be repeated if the...

Page 3: ...ons Fire hazard Wiring must comply with applicable electrical standards and include a properly sized fuse or circuit breaker Improper wiring can cause a fire resulting in injury or death Suggested wiring information is given as a guide only Please note that incorrect installation may invalidate the warranty The Watermaster IC is designed to work in conjunction with a 5 Amp automotive fuse see fuse...

Page 4: ...t TO CONNECT THE IC CONTROL UNIT BACK OF SOCKET Step 1 Switch off the 12V d c supply at the main panel isolator switch Step 2 Unplug the spade connections on the water inlet socket ensuring that you note the order of wires for reconnection with the Watermaster IC see Fig 1 Fig 2 Step 3 Unscrew and remove the pressure switch adjusting screw and locking nut see Fig 2 Step 4 Remove securing screw see...

Page 5: ...expelled turn off tap the pump should turn off after approximately 10 seconds TO CALIBRATE THE SYSTEM Step 1 Press and hold the calibration button until the green LED starts to flash after 1 3 seconds Fig 7 Step 2 Open the tap and the pump should start there maybe a short delay Step 3 After approximately 30 seconds turn off the tap Step 4 After approximately 10 seconds the pump should still be run...

Page 6: ... as per steps above in Section 6 To obtain efficient running and maximum pump life ensure the following There is sufficient water in the container Maximum pumping period is not more than 15 minutes All hose connections are firm and water tight The power supply is adequate low performance could result from a weak battery or reduced voltage due to undersized wiring we recommend wiring should be a mi...

Page 7: ...connections in pipework Recalibrate the system Diagnostic Codes To aid with troubleshooting the LED on the back of the Watermaster IC has a number of different flash codes as described in the table below Watermaster IC does not require any additional winterizing For details of how to drain your water system for winterizing please visit www whalepumps com rv For installation or serviceable parts ad...

Page 8: ...ster Simms Engineering Ltd 277 279 Old Belfast Road Belfast BT19 1LT Year mark first applied 2012 Limitations of use For use with EP1612 12V submersible pump only Name and position of person binding the manufacturer or authorized representative Signature Name Stanley McFarland Function Engineering Director Location Munster Simms Engineering Ltd 277 279 Old Belfast Road Northern Ireland BT19 1LT Da...

Page 9: ...ecifications without prior notice Illustrations are for guidance purposes only Please note that by contacting Whale Support you will be indicating your consent to receiving product updates recall information help guides and appropriate marketing messages from us via post email or telephone unless you indicated an objection to receiving such messages Munster Simms Engineering Ltd Old Belfast Road B...

Reviews: