INSTALLATION AND OPERATION MANUAL

Whale® Bilge IC Waste Pump Range

Page 2

English

Page 14

French

Page 26

German

Page 38

Italian

Page 50

Spanish

Page 62

Swedish

Page 74

Finnish

Model Number

Description

BP2083B

Gulper IC - 12 V d.c.

BP2085B

Gulper IC - 24 V d.c.

SI8284

Retail Bilge IC - Remote Mounted Bilge Kit 

12 V d.c.

SI8484

Retail Bilge IC - Remote Mounted Bilge Kit 

24 V d.c.

SI8222B

Bulk Strainer IC and Gulper IC- 

12 V d.c with 2m (6ft) cable

SI8224B

Bulk Strainer IC and Gulper IC- 

12 V d.c with 4m (12ft) cable

SI8422B

Bulk Strainer IC and Gulper IC- 

24 V d.c with 2m (6ft) cable

SI8424B

Bulk Strainer IC and Gulper IC- 

24 V d.c with 4m (12ft) cable

CONTENTS

Summary of Contents for Bilge IC Series

Page 1: ...V d c BP2085B Gulper IC 24 V d c SI8284 Retail Bilge IC Remote Mounted Bilge Kit 12 V d c SI8484 Retail Bilge IC Remote Mounted Bilge Kit 24 V d c SI8222B Bulk Strainer IC and Gulper IC 12 V d c with...

Page 2: ...ge pump Suitable as a primary bilge pump for boats up to 12 metres 39 4 ft designed to ISO15083 or as a secondary bilge pump on any vessel Fig 1 Typical Installation Gulper IC as a Remote Mounted Bilg...

Page 3: ...Replacement Gulper Pump Head AK2086B Deutsch Connector Extension Cable 6m 18ft Hose Connections Gulper IC Barbed connections either 19mm or 25mm 1 Strainer IC 19mm 3 4 port Port Orientation for Strai...

Page 4: ...FIG 9 CONNECT DEUTSCH CONNECTORS FIG 10 SECURING PIPEWORK FIG 11 STRAINER IC OPERATION TEST FIG 12 FOR CLEANING DETACH TOP COVER OF STRAINER IC FIG 13 FOR CLEANING UNSCREW VALVE HOUSING IC Intelligent...

Page 5: ...vented loop see Fig 1 Not suitable for pumping flammable liquids diesel chemicals etc Suitable for bilge water only NOTE Bilge pump capacities may not be sufficient to prevent flooding from rapid acc...

Page 6: ...re installing 11 i Location Choose a position to mount the pump that is dry and away from standing water and is free from obstacles Mount in a position with the shortest possible pipe run lengths 11 i...

Page 7: ...ht connections but do not over tighten clamp rings screws hose clips Fig 3 Gulper Installation Fig 4 Fit P clamp Screw p clamp to bulkhead ensuring it is located Approx 100 mm 4 from rear housing Fig...

Page 8: ...ump is protected against reverse polarity connection the inline fuse will blow NOTE Undersized wire in the circuit before the pump will reduce voltage when the pump is under load thus giving poor perf...

Page 9: ...GULPER IC TO STRAINER IC SEE FIG 1 Connect the pre wired Deutsch connectors on Gulper IC and Whale Strainer IC Fig 9 Connect Deutsch Connectors Use 19mm 3 4 or 25mm 1 smooth bore reinforced pipework t...

Page 10: ...Checks Whale advise that the boat s plumbing system is checked annually for leaks and obstructions Also a pump electrics check is advisable Before inspecting or replacing the diaphragm disconnect the...

Page 11: ...arefully remove the lid and clean the inside walls if necessary unscrew the valve housing assembly for further cleaning Isolator switch not working not switched on Pump circuit has no power Check the...

Page 12: ...section 14 Air leak in intake line Check hose connections are airtight Open pump head and check valves and diaphragm see section 14 Punctured pump diaphragm Replace the damaged part using service kit...

Page 13: ...r States relating to electromagnetic compatibility Low Voltage Directive 73 23 EEC amended by 93 68 EEC on the harmonization of the laws of the Member States relating to electrical equipment designed...