WD-100GR
Rev. 5.0 (202207)
Operating instructions
65
(40)
HACCP ALARM
FINAL RINSE DEFECT
PRESS RESET
The alarm can be reset with the reset button, but a check should be made on
the water flow in the machine (to ensure the water taps to the machine’s water
connection are open), and on the wash result after a completed wash cycle.
Contact service personnel!
(41) HACCP ALARM
FINAL RINSE DEFECT
MACHINE LOCKED
CALL SERVICE
The machine is locked when this alarm is activated. Check the water flow into
the machine,
- that the water taps to the machine’s water connection are open,
- that there is nothing wrong with the water supply to the machine, etc.
Contact service personnel!
(42) TIMEOUT WHEN
FILLING TANK
PRESS RESET TO
START FILLING AGAIN
Check that water taps connected to the machine are open. Check that the level
pipe is in place and its rubber sleeve achieves a good seal with the tank bottom.
Reset the alarm by pressing the reset button.
(105) TIMEOUT WHEN
FILLING BREAK TANK
PRESS RESET TO
START FILLING AGAIN
Check that water taps connected to the machine are open and there are no
problems on the water supply to the machine. Reset the alarm by pressing the
reset button. Contact service personnel if the alarm will not go out.
(43)
TIMEOUT WHEN
HEATING TANK
PRESS RESET
Reset the alarm by pressing the reset button. Contact service personnel if the
alarm recurs!
(44)
LOW TEMPERATURE
IN TANK
PRESS RESET
Reset the alarm by pressing the reset button. Contact service personnel if the
alarm recurs!
(45) HACCP ALARM
HEATING OF TANK
DEFECT
PRESS RESET
Reset the alarm by pressing the reset button.
(46) HACCP ALARM
HEATING OF TANK
DEFECT. MACHINE
LOCKED. CALL SERVICE
Contact service personnel!
(47) LOW TEMP.
BEFORE FINALRINSE
EXTENDED CHEMICAL
WASH
Reset the alarm by pressing the reset button. Check the wash results after the
wash cycle has finished.
(48) HACCP ALARM
HEATING OF BOILER
DEFECT
PRESS RESET
The alarm can be reset using the reset button, but service personnel should be
contacted as soon as possible.
(49) HACCP ALARM
HEATING OF BOILER
DEFECT. MACHINE
LOCKED. CALL SERVICE
Contact service personnel!
(50) WASHING
DETERGENT ALARM
ACTIVE CHECK
DETERGENT DEVICE
Check whether the machine is out of detergent. Add detergent. The alarm can
be reset by pressing the reset button. Contact service personnel if the alarm
recurs!
(51) HACCP ALARM
WASHING DETERGENT
FUNCTIONALITY DEFECT
PRESS RESET
Check whether the machine is out of detergent. Add detergent. Reset the alarm
by pressing the reset button. Contact service personnel if the alarm recurs!
ALARM MESSAGE
ACTION
Summary of Contents for WD-100GR
Page 2: ......