ALARM MESSAGE
ACTION
(0)
PLATFORM ERROR
Switch off the machine and restart it.
(63) POWER SUPPLY
FAILURE
CHECK THE
EMERGENCY SWITCH
Switch off the machine and restart it.
(98) HARDWARE ERROR
POWER ON FUNCTION
DEFECT
CALL SERVICE
Switch off the machine and restart it.
(61)
EMERGENCY STOP
ACTIVATED
PRESS RESET
Reset the emergency stop by turning the knob in the direction of the arrows.
Reset the alarm by pressing button (8).
(3)
NOMINAL VALUES
CORRUPTED IN MEMORY
CALL SERVICE
Contact service personnel!
(99)
THE MACHINE TYPE
HAS BEEN CHANGED
VERIFY THIS
Contact service personnel!
(2)
INPUT FAILURE ON
DIGITAL INPUTS
CALL SERVICE
Contact service personnel!
(100)
NOMINAL VALUES
RESTORED FROM UI
Reset with the reset button on the machine.
(4) COMMUNICATION ERR
BETWEEN CPU BOARD
AND I/O BOARD1
CALL SERVICE
Restart the machine!
(7) COMMUNICATION ERR
BETWEEN CPU BOARD
AND UI BOARD
CALL SERVICE
Restart the machine!
(66) SENSOR ERROR
CLEAN AND CHECK
FUNCTION FOR
LEVEL SENSORS
Clean the level sensors in the wash tank. Reset the alarm by pressing the reset
button.
(8)
OVERLOAD DOORS
ACTIVATED
CALL SERVICE
Contact service personnel!
(9)
OVERLOAD PUMPS
ACTIVATED
CALL SERVICE
Contact service personnel!
(10) HACCP ALARM
PUMP FUNCTIONALITY
DEFECT
PRESS RESET
Reset the alarm by pressing the reset button.