Flow Rates - check the product and concentrate flow rates to determine any change from the normal 

conditions.  Adjust the flows and pressures if necessary to maintain the proper settings.  If the pump 

pressure is 190 PSI and the recovery rate is too low, the membrane may be fouled and require 

cleaning. 

 

Recovery Rates - If the TDS level climbs or an odor develops, measure the amount of water coming 

out from the concentrate line, and then do the same for the product water line.  The difference in 

concentrate to product should be approximately 5 to 1.  If the ratio needs to be adjusted, it can be 

done by using the adjusting screw on the pump. 

 

NOTE 1 -

 Under no conditions should you allow the membrane to dry out.  Always keep moisture in the 

RO membrane assembly, and always keep the ends plugged (Use threaded plugs being careful not to 

over tighten, as a cracked end plug may result).  If freezing weather conditions exist, drain the water from 

the RO membrane assembly and plug the holes before shipping. 

 

NOTE 2 -

 For the most accurate TDS readings, let the RO unit run for at least 15 minutes. 

 

NOTE 3 -

 For the warranty to be valid, activated carbon must be used to remove the chlorine from the 

water supply.  Use a chlorine test kit to determine if any chlorine is in the reject water.  If it is, replace the 

activated carbon tank or cartridge.  If chlorine passes even with a new carbon filter, you need to get a 

larger one with greater capacity for chlorine removal. 

 

If you find yourself cleaning the system frequently, a change in the feedwater chemistry may be the cause.  

Only a detailed water analysis can determine the likely cause of membrane fouling.  Consult your water 

retailer or consult the XYLEM WET service department for information and pricing for membrane cleaning 

and/or water analysis services. 
DO NOT return the RO unit to XYLEM WET without first obtaining Return Merchandise 

Authorization(RMA).  Company will not be responsible for equipment, supplies, or materials returned 

without an RMA.  All shipments should be properly insured. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for CAK Series

Page 1: ...C Ca ak k N Na ak k W Wa at te er r P Pu ur ri if fi ic ca at ti io on n S Sy ys st te em m REMOVE 90 TO 98 OF THE TOTAL DISSOLVED SOLIDS AND 100 OF PARTICULATE CONTAMINANTS...

Page 2: ...s manual be read and understood before performing installation operation and maintenance of the system The equipment warranty may be voided if instructions are not followed correctly The information p...

Page 3: ...s Pressurized Water Hazardous Chemicals Noise Failure to follow good safety practices and the instructions included in this manual may result in damage to the unit its surroundings personal injury or...

Page 4: ...ll out the operator s log sheet completely and return to XYLEM WET to validate warranty NOTE Hardness and iron will foul the membranes and result in a decrease in the amount and quality of the water p...

Page 5: ...ced Clogged inlet filters As pre filters age and collect debris the pressure drop across the filter increases and flow decreases At some point the reduced pressure or flow may actually cause the syste...

Page 6: ...tio Rejection of the TDS Total Dissolved Solids is at least 90 at 185 PSI 78 F and 1000 PPM TDS NOTE If the RO pump pressure exceeds 190 PSI 1 Remove the acorn nut on the right side of the pump 2 Usin...

Page 7: ...poly fitting Put them aside and keep them as spares 7 Connect the P6UC4 Poly fitting to the ends of the each of the tubing connections removed step 3 The tubing connections are long enough to bend to...

Page 8: ...y done with the sample port See the SYSTEM LAYOUT drawing NOTE Higher levels of chlorine may require a larger carbon prefilter if one is needed contact your local sales representative 3 RO PUMP once e...

Page 9: ...eat build up can also cause leaks to develop and will cause fouling of the membranes VENTILATION Inadequate ventilation will cause the pump motor to overheat and cut out It will also cause leaks due t...

Page 10: ...change in water production is approximately 2 Thus if the water temperature is 5 degrees C the amount of water produced will be 40 less than at 25 degrees C TDS AND REJECTION RATE As the TDS total di...

Page 11: ...drain the water from the RO membrane assembly and plug the holes before shipping NOTE 2 For the most accurate TDS readings let the RO unit run for at least 15 minutes NOTE 3 For the warranty to be va...

Page 12: ...12...

Page 13: ...13 Part Number 07 MS 1020 Rev 3 October 2018...

Reviews: