Swing Out Rotors

Rotor Code

Rotor #

Max. Volume

Max. RPM

Max. RCF

L30-130

Rotor 1

4 x 100ml

4500

3164

L30-129

Rotor 2

4 x 50ml

4500

3485

L30-128

Rotor 3

6 x 50ml

4500

3530

L30-125

Rotor 4

16 x 15ml

4500

3485

L30-126

Rotor 5

12 x 15ml

4500

3485

L30-140

Rotor 25

32 x 10ml

4500

3164

L30-124

Rotor 26

2 x Microplates

4500

2377

Fixed Angle Rotors

Rotor Code

Rotor #

Max. Volume

Max. RPM

Max. RCF

L30-136

Rotor 7

4 x 100ml

4500

2559

L30-135

Rotor 8

4 x 50ml

4500

2644

L30-134

Rotor 9

6 x 50ml

4500

2644

L30-137

Rotor 10

24 x 15ml

4500

2852

L30-131

Rotor 11

16 x 15ml

4500

3144

L30-132

Rotor 12

12 x 15ml

4500

3144

L30-133

Rotor 13

8 x 15ml

4500

2644

L30-138

Rotor 46

30 x 15ml

4500

2729

Start and stop

The centrifugation can be initiated by pressing the start button once the desired 

operation is set. To stop the operation, press the stop button once. To open the lid, 

press the Stop/Open button once after the rotor comes to a stop.

Summary of Contents for 4500RPM Max

Page 1: ...1 PRODUCT MANUAL Multipurpose Lab Centrifuge 4500RPM Max Code 665 113...

Page 2: ...ion the unit can halt and resume operations without disturbing fragile samples To protect the samples further the centrifuge s intelligently designed airflow system ensures that the temperature of the...

Page 3: ...mum Rotor Capacity 4 x 100ml Maximum Speed RPM RCF g 4500 RPM g varies per rotor Speed Setting Range 500 to 4500 RPM Step of 100 RPM Speed Accuracy 100 RPM Time Setting Range 1 to 99 minutes and infin...

Page 4: ...or the rotor chamber the centrifuge must be cleaned carefully before resuming operations The centrifuge may be used for the specified applications only It must not be operated in a hazardous or flamm...

Page 5: ...tamination caused by aggressive agents the rotor must be cleaned immediately with a natural cleaning liquid Pay particular attention to the bores of the tubes If any damage is seen contact the service...

Page 6: ...ed as a lid open function of the centrifuge motor is not running 3 RPM RCF Single press to display the RPM and for the RPM LED to blink Long press the button to toggle the display between RPM and RCF...

Page 7: ...N the power switch located on the right of the unit ATTENTION Maintain a gap of three seconds between turning the power switch OFF and then turning it ON again Do not turn ON and OFF again immediately...

Page 8: ...ters Speed Time ACC DCC as described above To select the programs press the increment and decrement buttons All the parameters in the program will save automatically after the display stops blinking T...

Page 9: ...15ml 4500 3485 L30 140 Rotor 25 32 x 10ml 4500 3164 L30 124 Rotor 26 2 x Microplates 4500 2377 Fixed Angle Rotors Rotor Code Rotor Max Volume Max RPM Max RCF L30 136 Rotor 7 4 x 100ml 4500 2559 L30 1...

Page 10: ...osing and opening mechanism Contact the technical support team on 1800 358 101 Err 55 Rotor loaded asymmetrically Load the rotor symmetrically and restart the centrifuge Lid cannot be opened Spinning...

Page 11: ...ed States Canada Error Code Cause Corrective Steps Last run memory not displayed Turning the centrifuge ON immediately after turning it OFF Maintain a three second gap between turning the centrifuge O...

Page 12: ...Westlab in every discovery...

Reviews: