Ceiling Built-in Unit 

Stratus 

 

 

Installation, Operating & Maintenance Instructions 

 

 

W1267 WSW STRATUS Ceiling Extract O&M (Energy Label Version) Feb 15.docx

 

Page 2 

Westin 

 

 

 

1.  INTRODUCTION 

During  the  cooking  process,  there  will  be  heat,  vapours  and 
fumes  produced.  Your 

Westin  Ceiling  Extractor 

has  been 

designed  to  complement  your  kitchen  both  in  looks  and 
performance,  in  order  to  create  a  good  environment  for 
creative cooking. 

2.  IMPORTANT INFORMATION 

The  exhaust  air  must  not  be  discharged  into  a  flue  which  is 
used  for  exhausting  fumes  from  appliances  supplied  with 
energy other than electricity e.g. oil or gas-fired central heating 
boilers, gas-fired water heaters, etc. 

Requirements  of  the  relevant  authorities  concerning  the 
discharge of exhaust air must be complied with. 

Pay  particular  attention  to  fire  risk  when  frying.  To  minimise 
the risk  of  fire, all  instructions  relating  to  cleaning  the  grease 
filters and removing grease deposits must be adhered to. 

Do not flambé under the extractor. 

 
The clearance between the hob burners and the bottom 
surface of the extractor must be at least 750mm to prevent 
overheating of the extractor and its components. 

Please also note that a 90

o

 bend in flexible ducting will require 

215mm minimum headroom to give a smooth radius with no 
kinking. 

You are advised to install measures designed to reduce 
the incidence of cold draughts entering the property via 
any ductwork. 

 

For extractors with internal or inline motors, this 
should, at the very least, consist of an external duct 
termination with integrated non-return flaps (e.g. 
gravity shutter wall grille/louvre) and/or an inline 
backdraught shutter. 

 

For wall-mounted motors, an inline backdraught 
shutter is recommended.  

3.  EXTRACTION PERFORMANCE 

As its name suggests, this type  of  extractor  is  designed  to  fit 
into the ceiling void, with only the underside and outer flange 
visible when installed. 

Because fumes spread out as they rise, a unit larger than the 
hob  area  is  desirable,  although  not  always  possible.  The 
perimeter extraction system is designed to conceal the grease 
filters and to minimise fume escape. Warm cooking fumes that 
do  escape tend,  initially,  to  accumulate in  the highest  part  of 
the room, so situating the unit at the highest point is of benefit. 
It will perform best when it is situated directly over the hob.  

The  primary  influence  on  the  overall  performance  of  the 
extractor is the design of the ducting which takes the exhaust 
air from the extractor to the outside. The duct route should be 
a  prime  consideration  during  the  initial  stages  of  the  kitchen 
design  (Westin  do  not  recommend  recirculating  air  back  into 
the kitchen). 

Please note the following: 

  Easy  access  to  the  duct  route  during  installation  is 

important. Lack of access may require the “blind” fitting of 
flexible  ducting  (with  increased  risk  of  unseen  kinks  and 
impaired efficiency). 

  The  extractor  is  provided  with  a  spigot  suitable  for 

connecting 150mm diameter ducting. 

 

Note

: the cross-sectional area of 150mm diameter duct is 

the minimum area consistent with efficient extraction. 

  The most efficient configuration is to duct straight through 

an  outside  wall,  so  try  to  position  the  cooker  against  an 
outside wall when designing your kitchen. 

  Your  extractor can be  set  to vent  to  the  rear,  front,  left or 

right.  Use  the  exhaust  position  which  gives  the  shortest 
achievable  duct  route  and  least  number  of  bends.  Joist 
positions will often determine what is achievable.  

  Rigid  150mm  round  ducting  or  an  equivalent  flat  channel 

system  (available  from 

Westin) 

will  perform  best,  with 

semi-rigid (often referred to as flue liner) being the second-
best  solution.  Flexible  ducting  is  economical  but  it’s  use 
should be minimised as it gives the worst performance and 
should  only  be  used  for  short  duct  runs  (or  initial 
connection) and should be pulled taut to prevent significant 
losses in extraction efficiency. 

  For  maximum  efficiency,  ducting  should  be  kept  as  short 

as  possible  and  as  straight  as  possible  with  a  constant 
cross-sectional area being no less than that recommended 
by  Westin.  Bends  in  the  duct  will  also  degrade 
performance so the number of bends in a duct run should 
be  kept  to  a  minimum  and  be  gradual  and  smooth  to 
prevent  turbulence.  Avoid  kinks  in  flexible  ducting;  pull 
flexible  ducting  taut  over  straight  runs  to  ensure  that  the 
internal surface is as smooth as possible. 

4. 

INSTALLATION 

The extractor is designed for installation within a cut-out in the 
underside  of  the  kitchen  ceiling.  Alternatively,  it  may  be 
installed within a lowered area of ceiling or a soffit panel within 
your furniture – remember though that it is desirable to install 
directly into the ceiling (see section 3). 

 

 

Dimensioned drawings and illustrations to help with 

your installation can be found on page 7 onwards.

 

WARNING. 

Proper  care  must  be  taken  to  ensure  that  the  negative 
pressures  caused  by  high  performance  extraction 
systems  do  not  adversely  affect  the  safe  operation  of 
certain types of fuel-burning appliances (gas, oil or solid 
fuel),  including  those  installed  in  the  kitchen  and  also 
those installed in other parts of the house. 
Where  such  fuel-burning  appliances  are  installed, 
adequate  ventilation  MUST  be  provided  in  the  room  of 
installation,  located  and  sized  such  that  the  negative 
pressure  in  the  room  created  by  the  extractor  does  not 
exceed 4Pa. 
In case of doubt, do not operate the extractor and fuel-
burning  appliance(s)  simultaneously  and  consult  an 
appropriate (for the fuel type) expert for advice. 

ELECTRICAL SAFETY. 

This appliance requires an earth connection. 
Ensure  that  the  supply  voltage  corresponds  to  that 
marked on the rating label inside the extractor. 
The  extractor  must  be  isolated  from  the  electrical 
supply  before  carrying  out  any  cleaning  or 
maintenance operations. 

Summary of Contents for STRATUS Air

Page 1: ...NT DRAWINGS ILLUSTRATIONS 1 2 3 4 5 6 7 8 Unpacking Remove all items from the packaging Retain the packaging If items are missing or damaged please contact Westin for assistance The following items ar...

Page 2: ...flexible ducting with increased risk of unseen kinks and impaired efficiency The extractor is provided with a spigot suitable for connecting 150mm diameter ducting Note the cross sectional area of 150...

Page 3: ...n box it came in so that the top box hangs down into the box Open the filter concealment panel and remove the filter s Each exhaust position has 4 captive nuts onto which can be bolted either the exha...

Page 4: ...pe is configured differently No separate power supply is required for the external motor An electrician or Part P registered electrical installer should undertake any work associated with the electric...

Page 5: ...connect the electrical supply cord of the extractor to the spur Attach the ducting to the spigot using suitable clamps or straps available from Westin We do not recommend using duct tape as the only m...

Page 6: ...er or washing up detergent and warm water Painted surfaces should be cleaned using a soft cloth detergent and warm water Glass surfaces should be cleaned with a suitable glass cleaning agent Do not us...

Page 7: ...Ceiling Built in Unit Stratus Installation Operating Maintenance Instructions W1267 WSW STRATUS Ceiling Extract O M Energy Label Version Feb 15 docx Page 7 Westin...

Page 8: ...Operating Maintenance Instructions W1267 WSW STRATUS Ceiling Extract O M Energy Label Version Feb 15 docx Page 8 Westin Pop out lamp to reveal fixing holes Typical cut out detail Joists running in lin...

Page 9: ...2 7 and 8 Remote Motor Terminal Box Fig 1 Open Terminal Box Empty Terminal for Motor Connections Extractor Fig 2 Typical System SEM2 Shown Red Blue White Grey Black Green Yellow Brown Orange Yellow Pu...