Ceiling Built-in Unit 

Stratus 

 

 

Installation, Operating & Maintenance Instructions 

 

 

W1267 WSW STRATUS Ceiling Extract O&M (Energy Label Version) Feb 15.docx

 

Page 3 

Westin 

 

Please note the following. 

  The extractor is made up of two main parts: 

o

  The 

“top  box”

,  which  houses  the  exhaust  ducting 

spigot,  grease  filter,  electrical  connection  points  and 
any internal motor. 

o

  The 

“baseplate”

,  which  is  essentially  the  visible  parts 

when  installed  and  houses  the  lights,  hinged  filter 
concealment panel and outer frame. 

  The  ducting  spigot  must  be  set  to  the  required  outlet 

position  prior  to  installation  (Left,  Right,  Front,  Rear  or 
Top). 

  The Stratus “top box” has 3 possible duct spigot positions. 

It  is  easily  separated  from  the  baseplate  and  can  be 
rotated  through  180  degrees  in  order  to  achieve  all  5 
possible  outlet  directions.  It  is  secured  via  screws 
accessible only when the filter concealment panel is in the 
open position. 

  The extractor fixing holes are hidden behind the LED down 

lights,  which  can  easily  be  popped  out  to  reveal  four 
possible fixing locations behind each (only one fixing hole 
in each corner needs to be used). 

 

If your extractor is a recirculating model 

(optional extra 

and  not  the  standard  configuration)  then  adequate 
provision must be made for exhausted air to return into the 
kitchen - e.g. ducted out to a ceiling vent sited to minimise 
uncomfortable  draughts.  Failure  to  do  so  may  cause  the 
unit to overheat and fail (and will invalidate your warranty). 

4.1.  Opening the filter concealment panel.  

The panel is held shut with magnetic catches. 
Open  the  panel  by  grasping  it  close  to  the  corners  on  the 
catch side  (the  long edge  opposite  the hinges)  and pulling  to 
release  the  panel  from  the  magnets. Take care  not  to  let  the 
panel  fall  open  freely.  It  should  be  supported  and  moved 
carefully into the open position.  

4.2.  Setting the Duct Spigot Position.  

Your  extractor  ducting  spigot  can  be  set  to  vent  to  the  Left 
(factory default), Right, Front, Rear or Top.

 

The  front  of  the  unit,  when  installed,  is  the  side  with  the 
magnetic catches. 

Note: If you wish to vent upwards and space is restricted, then 
you  may  find  your  installation  easier  if  you  use  a  side  outlet 
position and put a bend in your ducting.

 

The “top box” exhaust spigot assembly refers to the removable 
150mm  ducting  spigot  plate,  which  in  the  case  of  Internal 
blower models has the motor attached to it. 

  As described earlier,  the  Stratus  “top box” has  3  possible 

duct  spigot  positions,  with  the  remainder  being  achieved 
by rotation of the top box through 180 degrees. 

To  change  the  exhaust  spigot  position  of  the  "top  box" 
proceed as follows: 

  Suspend the extractor on its back 

such that the “top box” 

is 

clear  of  the  ground.  This  is  best  achieved  by  placing  the 
product across  the  top of  the open  box it came in so that 
the 

"top box"

 hangs down into the box.  

  Open the filter concealment panel and remove the filter(s). 

  Each  exhaust  position  has 4  captive  nuts  onto  which  can 

be bolted either the exhaust spigot assembly or a blanking 
plate. 

Bolt the exhaust spigot assembly into the required location 
by swapping it with a blanking plate as necessary using a 
screwdriver. 

Note: For  internal blower models  (where  space  within  the 
top  box  is  limited)  only  the  screws  nearest  to  the  filter 
opening  need  to  be  fully  removed.  The  screws  farthest 
away need only to be backed off as the plate has slots for 
easier removal/replacement of the motor.  

To rotate the "top box" proceed as follows: 

  Suspend the extractor on its back 

such that the “top box” 

is 

clear  of  the  ground.  This  is  best  achieved  by  placing  the 
product across  the  top of  the open  box it came in so that 
the 

"top box"

 hangs down into the box.  

  Open  the  filter  concealment  panel  to  reveal  the  fixing 

screws  securing  the 

“top  box”

  to  the 

“baseplate”

  and 

remove the screws. 

  Carefully lift  the 

"top  box"

  out  of  the 

"baseplate"

  opening, 

rotate it to face the required direction and carefully refit it in 
its new position, taking care not to trap any wires. Secure it 
with the screws previously removed. 

 

4.3.  Revealing the Fixing Holes.  

The  extractor  is  fitted  with  4  high  intensity  LED  lamp 
assemblies  (one  in  each  corner)  which  conceal  the  fixing 
holes behind them. These are easily popped out to reveal four 
possible fixing locations behind each. 

The  best  way  to  remove  the  lamps  for  initial  installation  is  to 
pop  them  out  from  behind.  25mm  finger  holes,  centred  on 
each lamp, are provided in the baseplate to enable this. 

The  lamps  remain  attached  to  their  electrical  cables  so  care 
must be taken not to damage the wires during installation. 

Note:  The  fixing  holes  can  be  revealed  after  the  unit  is 
installed by carefully pulling the lamps out from underneath. 

Four fixing holes will now be visible in the corner of each lamp 
opening. 

You should only need to use 1 of the holes in each corner to 
secure the unit in position. 

4.4.  Prepare Opening. 

Prepare  an  opening  in  the  ceiling  into  which  the  unit  will  be 
fitted  (see  table  below).  Reinforce  the  opening  as  necessary 
and make suitable provisions for the screws that will hold the 
unit in place. 

Unit Size (mm) 

(Width x Depth) 

Cut-out Size (mm) 

(Width x Depth)

 

900 x 440 

860 x 400 

1200 x 440 

1160 x 400 

900 x 800 

860 x 760 

1200 x 800 

1160 x 760 

Tip: To avoid the need to box down from the ceiling, consider 
the joist direction, ceiling thickness (and possibly lowering the 
ceiling slightly). As much of the baseplate only intrudes above 
the  finished  ceiling  by  25mm,  (see  diagrams  on  Page  7 
Onwards)  boxing  down  can  usually  be  avoided  with  minimal 
alterations to the ceiling arrangement. 

Important. 

The "top box" will need to be angled during 

removal and refitting to allow the duct spigot, 

electrical connection points and any cables to 

clear the opening in the "baseplate".

 

Summary of Contents for STRATUS Air

Page 1: ...NT DRAWINGS ILLUSTRATIONS 1 2 3 4 5 6 7 8 Unpacking Remove all items from the packaging Retain the packaging If items are missing or damaged please contact Westin for assistance The following items ar...

Page 2: ...flexible ducting with increased risk of unseen kinks and impaired efficiency The extractor is provided with a spigot suitable for connecting 150mm diameter ducting Note the cross sectional area of 150...

Page 3: ...n box it came in so that the top box hangs down into the box Open the filter concealment panel and remove the filter s Each exhaust position has 4 captive nuts onto which can be bolted either the exha...

Page 4: ...pe is configured differently No separate power supply is required for the external motor An electrician or Part P registered electrical installer should undertake any work associated with the electric...

Page 5: ...connect the electrical supply cord of the extractor to the spur Attach the ducting to the spigot using suitable clamps or straps available from Westin We do not recommend using duct tape as the only m...

Page 6: ...er or washing up detergent and warm water Painted surfaces should be cleaned using a soft cloth detergent and warm water Glass surfaces should be cleaned with a suitable glass cleaning agent Do not us...

Page 7: ...Ceiling Built in Unit Stratus Installation Operating Maintenance Instructions W1267 WSW STRATUS Ceiling Extract O M Energy Label Version Feb 15 docx Page 7 Westin...

Page 8: ...Operating Maintenance Instructions W1267 WSW STRATUS Ceiling Extract O M Energy Label Version Feb 15 docx Page 8 Westin Pop out lamp to reveal fixing holes Typical cut out detail Joists running in lin...

Page 9: ...2 7 and 8 Remote Motor Terminal Box Fig 1 Open Terminal Box Empty Terminal for Motor Connections Extractor Fig 2 Typical System SEM2 Shown Red Blue White Grey Black Green Yellow Brown Orange Yellow Pu...

Reviews: