ALLURE™   WS15 SERIES

RANGE  HOOD  

!

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO 

PERSONS, OBSERVE THE FOLLOWING:
1.  Use this unit only in the manner intended by the manufacturer. If you have 

questions, contact the manufacturer at the address or telephone number 

listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service panel and 

lock the service disconnecting means to prevent power from being 

switched on accidentally. When the service disconnecting means cannot 

be locked, securely fasten a prominent warning device, such as a tag, to 

the service panel.

3.  Installation work and electrical wiring must be done by a qualified 

person(s) in accordance with all applicable codes and standards, includ-

ing fire-rated construction codes and standards.

4.  Sufficient air is needed for proper combustion and exhausting of gases 

through the flue (chimney) of fuel burning equipment to prevent backdraft-

ing. Follow the heating equipment manufacturer’s guideline and safety 

standards such as those published by the National Fire Protection As-

sociation (NFPA), and the American Society of Heating, Refrigeration and 

Air Conditioning Engineers (ASHRAE), and the local code authorities.

5.  When cutting or drilling into wall or ceiling, do not damage electrical wiring 

and other hidden utilities.

6.  To reduce the risk of fire or electric shock, do not use this range hood 

with an additional speed control device.

7.  Ducted fans must always be vented to the outdoors.
8.  To reduce the risk of fire, use only metal ductwork.
9.  Use with approved cord-connection kit only.
10.This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

1.  Never leave surface units unattended at high settings. Boilovers cause 

smoking and greasy spillovers that may ignite. Heat oils slowly on low 

or medium settings.

2.  Always turn hood ON when cooking at high heat or when cooking flaming 

foods.

3.  Clean ventilating fans frequently. Grease should not be allowed to 

accumulate on fan or filter.

4.  Use proper pan size. Always use cookware appropriate for the size of 

the surface element.

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A 

RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*

1.  SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, 

then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the 

flames do not go out immediately, EVACUATE AND CALL THE FIRE 

DEPARTMENT.

2.  NEVER PICK UP A FLAMING PAN — You may be burned.
3.  DO NOT USE WATER, including wet dishcloths or towels - violent steam 

explosion will result.

4.  Use an extinguisher ONLY if:

A.  You know you have a Class ABC extinguisher and you already know 

how to operate it.

B.  The fire is small and contained in the area where it started.
C.  The fire department is being called.
D.  You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.

ALLURE

WS15 SERIES

RANGE HOODS

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with 

the homeowner.
Homeowner: Operating and 

Cleaning information on page 5.

Page 1

CAUTION

1.  For indoor use only.
2.  For general ventilating use only. Do not use to exhaust hazardous or 

explosive materials and vapors.

3.  To avoid motor bearing damage and noisy and/or unbalanced impellers, 

keep drywall spray, construction dust, etc. off power unit.

4.  For best capture of cooking impurities, your range hood should be 

mounted so that the top of the hood is 24-30” above the cooking surface.

5.  Please read specification label on product for further information and 

requirements.

TABLE OF CONTENTS

This manual is divided into sections as follows:

  “PREPARE HOOD LOCATION”

Run ductwork from roof or wall cap, and electrical wiring from service 

panel - to installation location

  “PREPARE THE HOOD”

Get your hood ready for installation

  “CONNECT WIRING”

Make electrical wiring connections to hood

  “INSTALL HOOD”

Secure hood to cabinet and ductwork - install bulbs and filters

  “OPERATION”

How to use the hood controls

  “CLEANING”

Keep your hood in top working condition

  “SERVICE PARTS”

Part numbers and exploded view of hood components

  “WARRANTY”

One-year limited warranty and how to contact us

NOTE 

If hood is to be installed Non-Ducted:

 

   Purchase a set of (2) non-ducted filters from your   

local distributor or retailer and attach them to the   

aluminum mesh filters.

Patent No.:
US D450, 829 S

!

 FOR DOMESTIC COOKING ONLY 

!

Register your product online at: www.nutone.com/register

Summary of Contents for WS15 SERIES

Page 1: ...t TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may be burned 3 DO NOT USE WATER including wet dishcloths or t...

Page 2: ...ILTERS 1 Determine whether hood will discharge vertically 3 x 10 or 7 Round horizontally 3 x 10 only or non ducted For vertical or horizontal discharge run ductwork between the hood location and a roof cap or wall cap For best results use a minimum number of transitons and elbows 2 Use diagrams below for proper placement of ductwork and electrical cutout in cabinet or wall For a non ducted install...

Page 3: ...th one 1 screw NOTE Be care ful not to discon nect any wires 9 Rotate baffle Re insert baffle into air chute as shown so that baffle tabs fit all the way into slots in air chute An audible click will be heard when fully installed This will close off the air flow through the non ducted slots on top of hood 10 Re install air chute re connect wire harness and replace light panel NOTE Be careful not t...

Page 4: ...NOCKOUT Remove for 3 x 10 Vertical for 7 Round Discharge SEMI CIRCULAR DUCT KNOCKOUT Remove for 7 Round Discharge 13 7 Round Ducted Discharge Only Re install 7 Round Duct Plate removed in Step 1 under PREPARE THE HOOD section Install a 7 round damper purchase separately Damper flap must open freely in direction of air flow away from range hood 12 3 x 10 Ducted Discharge Only Attach Damper Duct Con...

Page 5: ...t Sentry is on the light above fan button 3 will flash on and off rapidly After the temperature has lowered to normal the fan will change to the setting prior to the Heat Sentry turning on Fuse The hood control contains a fuse to protect it from power surges If the fuse has opened blown the green fan level indicators will operate properly when the fan buttons switches are pressed but the fan and l...

Page 6: ...0508 7 Round Duct Plate includes hardware 2 R740013 Damper Duct Connector includes hardware 3 R602017 Screw 8 18 x Hex 2 in package 4 99091152 Nameplate 5 R602534 Screw 8 18 x 3 8 2 in package 6 R602533 Ground Screw 2 req 7 98010725 Wiring Cover includes hardware 8 Rivet Pop 125 dia 9 R169016 Filter Spring Kit 10 R169002 Motor Mounting Screw 3 each part 11 R99080535 Motor includes Motor Mounting K...

Page 7: ... LO SIGUIENTE 1 AHOGUE LAS LLAMAS con una tapa ajustada o charola de metal después apague la hornilla TENGA CUIDADO A FIN DE EVITAR QUEMADURAS Si las llamas no se apagan de inmediato EVACUEYAVISEA LOS BOMBEROS 2 NO LEVANTE NUNCA UNA SARTEN QUE ESTE EN LLAMAS Usted se podrá quemar 3 NO UTILICE AGUA incluyendo toallas de cocina mojadas puede resultar una explosión de vapor violenta 4 Utilice un exti...

Page 8: ...ana va a ser vertical conducto de 8 3 cm x 25 4 cm 3 x 10 o conducto redondo de 17 8 cm 7 horizontal sólo conducto de 8 3 cm x 25 4 cm 3 x 10 o si es un sistema sin conductos En el caso de descarga vertical u horizontal tienda los conductos entre el lugar donde va a instalar la campana y la tapa de techo o la tapa de pared Para obtener los mejores resultados utilice el número mínimo de transicione...

Page 9: ...r ningún cable 8 Quite el deflec tor del conducto para aire 9 Gire el deflec tor Vuelva a insertar el deflector en el conducto para aire de manera según lo dem ostrado que las aletas entren totalmente en las ranuras del conducto para aire Un tecleo audible será oído cuando está insta lado completamente Esto se cerrará del aire atraviesa las ranuras sin conduc tos encima de la campana 10 Reinstale ...

Page 10: ...te en el caso de descargas con conductos redondos de 17 8 cm 7 12 Sólo para descargas con conductos de 8 3 cm x 25 4 cm 3 x 10 Coloque el conectador del regulador de tiro conducto sobre la abertura del agujero ciego Asegúrese de que el pivote del regulador de tiro quede lo más cerca posible del borde superior posterior de la campana Quite la cinta de la aleta del regulador de tiro CONECTOR DEL REG...

Page 11: ... que se encuentra sobre el pulsador del ventilador destellará 2 Si el ajuste del ventilador está apagado cuando Heat Sentry está funcionando la luz que se encuentra sobre el pulsador 3 del ventilador destellará rápidamente Cuando la temperatura disminuye hasta el valor normal el ventilador regresará al ajuste que tenía antes de que la característica Heat Sentry se encendiera Fusible El control par...

Page 12: ... una garantía implícita por lo que la limitación antes mencionada puede no aplicarse a usted LA OBLIGACION DE BROAN NUTONE DE REPARAR O REEMPLAZAR SIGUIENDO EL CRITERIO DEBROAN NUTONE DEBERASERELUNICOYEXCLUSIVORECURSOLEGALDELCOMPRADOR BAJOESTAGARANTIA BROAN NUTONENOSERARESPONSABLEPORDAÑOSINCIDENTALES CONSIGUIENTES O POR DAÑOS ESPECIALES QUE SURJAN A RAIZ DEL USO O DESEMPEÑO DEL PRODUCTO Algunos es...

Reviews: