background image

Page 8

ALLURE™   WS15 SERIES

RANGE  HOOD  

12,7 cm

19,1 cm

26,7 cm

3,8 cm

,

,

35,4 cm

35,4 cm

TORNILLOS PARA EL MONTAJE DE LA CAMPANA (4)

12,7 cm

19,1 cm

FONDO DEL GABINETE

13,3 cm

13,3 cm

CUÑAS DE MADERA

(sólo gabinetes de

fondo empotrado)

3,2 cm

LÍNEA

CENTRAL

5 cm

ORIFICIO DE ACCESO PARA

LOS CABLES ELÉCTRICOS

(en el fondo del gabinete)

26,7 cm

3,8 cm

FRENTE DEL GABINETE

ORIFICIO DE ACCESO

DEL CONDUCTO HORIZONTAL

35,4 cm

35,4 cm

PLAFÓN

GABINETE

TAPA DE PARED

TAPA DE TECHO

CAMPANA

CAMPANA

CONDUCTO DE

8,3 cm x 25,4 cm O

REDONDO DE 17,8 cm

(para descarga vertical)

CABLEADO ELÉCTRICO

DOMÉSTICO (Parte superior

o posterior de la campana)

CONDUCTO DE

8,3 cm x 25,4 cm

(para descarga

horizontal)

De 45,7 cm a 60,9 cm

SOBRE LA SUPERFICIE

PARA COCINAR

PREPARACIÓN DEL LUGAR DONDE 

SE VA A INSTALAR LA CAMPANA

PREPARACIÓN DE LA CAMPANA

1

 

Quite la 

placa del conducto redondo de 17.8 cm (7”) de la parte 

superior de la campana. Colóquela aparte, con los tornillos de 

montaje.

2

 

Quite la cinta que sujeta los filtros en su lugar. Tire hacia abajo 

de mango/pestillo y sáquelos levantándolos. Coloque los filtros 

a un lado.

PLACA DEL CONDUCTO 

REDONDO DE 17.8 CM (7”)

FILTROS

Determine si la descarga de la campana va a ser vertical [conducto 

de 8.3 cm x 25.4 cm (3 ¼” x 10”) o conducto redondo de 17.8 cm 

(7”)], horizontal [sólo conducto de 8.3 cm x 25.4 cm (3 ¼” x 10”)] o 

si es un sistema sin conductos. En el caso de descarga vertical u 

horizontal, tienda los conductos entre el lugar donde va a instalar 

la campana y la tapa de techo o la tapa de pared. Para obtener 

los mejores resultados, utilice el número mínimo de transiciones 

y codos.

Utilice los siguientes diagramas para colocar adecuadamente los 

conductos y hacer el corte exacto para la conexión eléctrica en 

el gabinete o en la pared. En el caso de aquellas instalaciones 

en sistemas sin conductos, NO haga ningún orificio de acceso 

para el conducto.

3

 

Haga las conexiones del cableado doméstico entre el panel de 

servicio y el lugar donde va a instalar la campana.

SISTEMA VERTICAL DE CONDUCTOS DE 8.3 cm x 25.4 cm (3 ¼” x 10”)

SISTEMA VERTICAL DE CONDUCTOS 

REDONDOS DE 17.8 CM (7”)

CAMPANA EXTRACTORA

SERIE WS15 ALLURE™

Página 8

PREPARACIÓN DEL LUGAR DONDE 

SE VA A INSTALAR LA CAMPANA

SISTEMA HORIZONTAL DE CONDUCTOS DE 8.3 cm x 25.4 cm (3 ¼” x 10”)

CUÑAS DE MADERA

(sólo gabinetes de fondo empotrado)

FRENTE DEL GABINETE

FONDO DEL

GABINETE

9,5 cm

0,32 cm

1,9 cm

ORIFICIO DE ACCESO DEL

CONDUCTO HORIZONTAL

13,3

cm

13,3

cm 19,1 cm

TORNILLOS PARA
EL MONTAJE DE
LA CAMPANA (4)

LÍNEA

CENTRAL

ORIFICIO DE ACCESO

PARA LOS CABLES

ELÉCTRICOS (en la pared)

35,4 cm

35,4 cm

Summary of Contents for WS15 SERIES

Page 1: ...t TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may be burned 3 DO NOT USE WATER including wet dishcloths or t...

Page 2: ...ILTERS 1 Determine whether hood will discharge vertically 3 x 10 or 7 Round horizontally 3 x 10 only or non ducted For vertical or horizontal discharge run ductwork between the hood location and a roof cap or wall cap For best results use a minimum number of transitons and elbows 2 Use diagrams below for proper placement of ductwork and electrical cutout in cabinet or wall For a non ducted install...

Page 3: ...th one 1 screw NOTE Be care ful not to discon nect any wires 9 Rotate baffle Re insert baffle into air chute as shown so that baffle tabs fit all the way into slots in air chute An audible click will be heard when fully installed This will close off the air flow through the non ducted slots on top of hood 10 Re install air chute re connect wire harness and replace light panel NOTE Be careful not t...

Page 4: ...NOCKOUT Remove for 3 x 10 Vertical for 7 Round Discharge SEMI CIRCULAR DUCT KNOCKOUT Remove for 7 Round Discharge 13 7 Round Ducted Discharge Only Re install 7 Round Duct Plate removed in Step 1 under PREPARE THE HOOD section Install a 7 round damper purchase separately Damper flap must open freely in direction of air flow away from range hood 12 3 x 10 Ducted Discharge Only Attach Damper Duct Con...

Page 5: ...t Sentry is on the light above fan button 3 will flash on and off rapidly After the temperature has lowered to normal the fan will change to the setting prior to the Heat Sentry turning on Fuse The hood control contains a fuse to protect it from power surges If the fuse has opened blown the green fan level indicators will operate properly when the fan buttons switches are pressed but the fan and l...

Page 6: ...0508 7 Round Duct Plate includes hardware 2 R740013 Damper Duct Connector includes hardware 3 R602017 Screw 8 18 x Hex 2 in package 4 99091152 Nameplate 5 R602534 Screw 8 18 x 3 8 2 in package 6 R602533 Ground Screw 2 req 7 98010725 Wiring Cover includes hardware 8 Rivet Pop 125 dia 9 R169016 Filter Spring Kit 10 R169002 Motor Mounting Screw 3 each part 11 R99080535 Motor includes Motor Mounting K...

Page 7: ... LO SIGUIENTE 1 AHOGUE LAS LLAMAS con una tapa ajustada o charola de metal después apague la hornilla TENGA CUIDADO A FIN DE EVITAR QUEMADURAS Si las llamas no se apagan de inmediato EVACUEYAVISEA LOS BOMBEROS 2 NO LEVANTE NUNCA UNA SARTEN QUE ESTE EN LLAMAS Usted se podrá quemar 3 NO UTILICE AGUA incluyendo toallas de cocina mojadas puede resultar una explosión de vapor violenta 4 Utilice un exti...

Page 8: ...ana va a ser vertical conducto de 8 3 cm x 25 4 cm 3 x 10 o conducto redondo de 17 8 cm 7 horizontal sólo conducto de 8 3 cm x 25 4 cm 3 x 10 o si es un sistema sin conductos En el caso de descarga vertical u horizontal tienda los conductos entre el lugar donde va a instalar la campana y la tapa de techo o la tapa de pared Para obtener los mejores resultados utilice el número mínimo de transicione...

Page 9: ...r ningún cable 8 Quite el deflec tor del conducto para aire 9 Gire el deflec tor Vuelva a insertar el deflector en el conducto para aire de manera según lo dem ostrado que las aletas entren totalmente en las ranuras del conducto para aire Un tecleo audible será oído cuando está insta lado completamente Esto se cerrará del aire atraviesa las ranuras sin conduc tos encima de la campana 10 Reinstale ...

Page 10: ...te en el caso de descargas con conductos redondos de 17 8 cm 7 12 Sólo para descargas con conductos de 8 3 cm x 25 4 cm 3 x 10 Coloque el conectador del regulador de tiro conducto sobre la abertura del agujero ciego Asegúrese de que el pivote del regulador de tiro quede lo más cerca posible del borde superior posterior de la campana Quite la cinta de la aleta del regulador de tiro CONECTOR DEL REG...

Page 11: ... que se encuentra sobre el pulsador del ventilador destellará 2 Si el ajuste del ventilador está apagado cuando Heat Sentry está funcionando la luz que se encuentra sobre el pulsador 3 del ventilador destellará rápidamente Cuando la temperatura disminuye hasta el valor normal el ventilador regresará al ajuste que tenía antes de que la característica Heat Sentry se encendiera Fusible El control par...

Page 12: ... una garantía implícita por lo que la limitación antes mencionada puede no aplicarse a usted LA OBLIGACION DE BROAN NUTONE DE REPARAR O REEMPLAZAR SIGUIENDO EL CRITERIO DEBROAN NUTONE DEBERASERELUNICOYEXCLUSIVORECURSOLEGALDELCOMPRADOR BAJOESTAGARANTIA BROAN NUTONENOSERARESPONSABLEPORDAÑOSINCIDENTALES CONSIGUIENTES O POR DAÑOS ESPECIALES QUE SURJAN A RAIZ DEL USO O DESEMPEÑO DEL PRODUCTO Algunos es...

Reviews: