Using
2. Select the correct charging mode by repeatedly pressing the
mode button (A) until the resp. LED for the correct charging
mode (1 - 6) lights up. By pressing the mode button repeatedly,
the charger turns to the next charging mode.
Now the battery charging state LED (G) lights up.
Battery Charging State
Charging
Status
Charging
Phase
Flash
OFF OFF OFF Below
25%
Diagnosis
&
Recovery
ON
Flash
OFF
OFF
Below 50% Bulk Charge 1
ON
ON
Flash
OFF
Below 75% Bulk Charge 2
ON ON ON Flash
Below
100%
Absorption
ON ON ON ON Fully
charged
Trickle /
Maintenance
Diagnosis
and Recovery
The diagnostic function automatically checks
battery status and detects the voltage.
Charging
Charging to 80% of the energy
1) Charging with high rate: Charger delivers
constant current of 7 A until the voltage reaches
to 12.8 V resp. a current of 3.5 A is delivered until
the voltage reaches 25.6 V.
2) Charging with medium rate: Charger delivers
constant current of 5 A (drops to 3 A) until the
voltage reaches to 14.1 V resp. a current of 3 A
is delivered until the voltage reaches 28.2 V.
FULL