![Westfalia 20 58 07 Instruction Manual Download Page 29](http://html1.mh-extra.com/html/westfalia/20-58-07/20-58-07_instruction-manual_962857029.webp)
24
Battery Type and Settings
Symbol Mode
Setting
Details
1
28.8 V/3.5 A This mode is normally
suitable for 24 V WET, MF
and GEL batteries with a
capacity of 14-120 Ah.
2
29.4 V/3.5 A This mode is recommended
for several 24 V AGM
batteries with a capacity of
14-120 Ah. It is suitable for
charging batteries in sub-
zero temperatures.
3
14.4 V/7 A
This mode is normally
suitable for 12 V WET, MF
and GEL batteries with a
capacity of 14-230 Ah.
4
14.7 V/7 A
This mode is recommended
for several 12 V AGM
batteries with a capacity of
14-230 Ah. It is suitable for
charging batteries in sub-
zero temperatures.
5
13.6 V/5 A
Supply
a) Maintenance of 12 V SLA
batteries with a capacity of
14-230 Ah – LED (D) blinks.
b) The charger is used as a
power source with constant
13.6 V / 5 A – LED (D) is
switched on permanently.
6 16
V/1.5
A
BOOST
For recovering 12 V batteries
with a capacity of 14-230 Ah.
16V BOOST
12
☼
Á
12
☼
Á
24
☼
Á
24
☼
Á
13.6V SUPPLY