Document: 1784en02.doc
QWTIME III MASTER CLOCK
Author: PM
Date: 2008-11-07
User Manual
Page: 44 of 61
WESTERSTRAND URFABRIK AB
P.O. Box 133
Tel. +46 506 48000
Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA
Fax. +46 506 48051
E-mail:
Setup RS232/485 port
Type of protocol
Name of the transmission / reception protocol used in the module. The following protocols are available.
1
: General 2-way-communication protocol.
2, 3, 5 and 7 : Automatic time message protocols.
NMMI
:NMEA 0183, ZDA Time string, transmitted every minute.
NMSE
:NMEA 0183, ZDA Time string, transmitted every second.
Type of time
Type of time received or transmitted.
LT = Local Time.
NT = Normal Time (winter time).
UTC = Universal Time Coordinated.
-3- LT
1200 7E1
Type of time
Data format
Type of protocol
Baudrate