Setup sync. source
Below is a description of the different configuration parameters available in the setup menu for
sync. source
.
Please remark that if default settings are used no configuration is needed.
Type of synchronisation
State type of external synchronisation. The following time sources can be selected:
--------
No external synchronisation.
DCF77
Radio synchronisation DCF77.
RDS
Radio synchronisation RDS.
GPS
Radio synchronisation GPS.
MSF
Radio synchronisation MSF/RUGBY.
1/1M SYNC
Polarised 1/1-minute impulse, sync.
1/2M SYNC
Polarised 1/2-minute impulse, sync.
1/1M SLAVE
Polarised 1/1-minute impulse, slave.
1/2M SLAVE
Polarised 1/2-minute impulse, slave.
TC
Time code type hard wired DCF.
FMSF
Finnish FM time signal.
NTP CLIENT
The Master Clock is NTP client*
*Only applicable if the Master Clock is equipped with option Ethernet.
Alarm limit
The configuration parameter
Alarm limit
specifies the time delay before the radio alarm is activated. Default
setting is that the radio alarm is inactivated, AL.LIMIT --h--m.
DCF77
AL. LIMIT 12h00m
Type of synchronisation