Document: 1632en03.doc
WESTERSTRAND
Author: CAn
Date: 2003-09-03
Page: 10 of 12
WESTERSTRAND URFABRIK AB
Box 133
Tel. +46 506 48000
Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA
Fax. +46 506 48051
e-mail:
Setting of synchronisation source – function F6
The master clock is prepared for synchronisation via DCF/RDS (GPS optional) or minute impulse.
When the master clock is synchronised, the dot between hours and minutes is flashing each second.
When the clock is in normal mode, press
F
to select function F6.
Function for selection of synchronisation source. DCF (RDS/GPS) or
minute impulse (1/1 minute) can be selected. Select with
P
.
Sy dC = DCF (or RDS/GPS)
Sy Im = Minute impulse
Change with
P
. Accept with
F
.
Press
R
to return or continue with the next function (press
F
).
Special functions
To erase all programmed signal points for the relay output:
1) Turn OFF the master clock.
2) Press buttons
R
and
P
while the master clock is turned on.
The message ”dELE” is displayed, indicating that the erasure is completed.
Program reset
Restart of the master clock program. Already programmed signal points for the relay are intact but the real time
must be programmed with function F1 (and F2 for the slave clocks).
1) Turn OFF the master clock.
2) Press buttons
R
,
F
and
P
while the master clock is turned on.
The clock is restarted and ”- - - - ” is shown in the display.
F 6
S y d C
F 6
2 3 . 5 9