Set slave clock time– function F2
When the clock is in normal mode, press
F
to select function F2.
Function for correction of slave clocks. Select with
P
.
Note: Set the time shown by the slave clocks. The time of the slave clock
is automatically adjusted by rapid impulses or by inhibition of impulses.
Hour. Change with
P
. Accept with
F
.
Minute. Change with
P
. Accept with
F
.
Press
R
to return or continue with the next function (press
F
).
Note: If the slave clock is one minute from correct time, reverse the slave clock connection wires.
F 2
H 0 0
n 0 0
F 2
2 3 . 5 9