3. Check of motor before mounting of hands 

 

At delivery the device is set to full hour (e.g 12.00). The red arrow (6) then points to 0-mark of the setting 
plate (1). 
 
1.  Check that the arm of the micro switch (10) is in position shown as 10 B on the sketch above.  

- If so, continue to  2. 
- If not, (which means (10) is in the same position as 10B on the sketch) carry on as follows:  

 

Turn wheel (2) clockwise or anti -clockwise until the arm of the micro switch enters the notch  position 10 B 
in the wheel underneath the curve (11).  

 
2.  Check that the pin (3) fit straight into the hole (4), which should be positioned  straight under the pin (3), 

when the P-arm (5) is pressed down. In this position the red arrow (6) should point straight to the 0-mark on 
the graded disc. (1) 
- If so , continue mounting the hands. ( see p.5.1 below) 
- If not adjust as follows:  

 

A.

 

Move the brass wheel (2) slightly anti-clockwise until pin (3) is just over hole (4) 

B.

 

Press the P-arm (5) so the pin (3) enters hole (4) and keep it pressed down. This step releases the 
synchronous motor. 

C.

 

Turn the minute hand drive (9) anti-clockwise until the red arrow (6) points straight to 0-mark on the 
setting plate. 

D.

 

Release the ‘press down’ of the P-arm. 

 
Proceed to mounting of hands p.5.1 (see below).  
 
 
 

4. Mounting of hands. 

 
1.

 

Mount the hour hand on the shaft with it´s needle point aiming straight to 12. 

 
2.

 

Fasten the hour hand carefully. 

 
3.

 

Mount the minute hand on the shaft wit it’s needle point aiming straight to 12. 

4.

 

IMPORTANT!

 There should be some space on the shaft between the minute- and hours hand. 

 
5.

 

Fasten the minute hand carefully. 

Summary of Contents for 115000-00

Page 1: ...synchronous motor for LMV 3 3 Check of motor before mounting of hands 4 4 Mounting of hands 4 Mounting of hands version 115014 00 LMV UV 5 5 Installation and test 5 6 Resetting Setting of correct tim...

Page 2: ...llector The impulse collector includes an impulse controller which based on a cam and a micro switcher controls the current to the synchronus motor When the contact points of the switcher are closed t...

Page 3: ...051 E mail info westerstrand se 2 Sketch of synchronous motor for LMV 1 Setting plate 8A Terminal for connection 230VAC 2 Drive of brass 8B Terminal for Ground connection 3 Pin 9 Minute drive 4 Hole f...

Page 4: ...be positioned straight under the pin 3 when the P arm 5 is pressed down In this position the red arrow 6 should point straight to the 0 mark on the graded disc 1 If so continue mounting the hands see...

Page 5: ...Connect to 230 VAC via the terminal 8A and protective earth to terminal 8B When installed a readily accessible disconnect device shall be incorporated in the fixed wiring 2 Connect the impulse wire f...

Page 6: ...w 6 points straight to 0 mark on the setting plate 1 If not turn theminute wheel 9 anti clockwise until that position When the red arrow 6 points at 0 on the setting plate 1 this means that the moveme...

Page 7: ...he movement begins to forward the hands to correct time It will take some minutes the time depends on how long the power failure has lasted until the movement has reset the hands After the movement ha...

Page 8: ...RIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Lubrication of driving mechanism 1 Angle gear bearing 2 Centre shaft 3 Impuls co...

Page 9: ...B Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Lubrication of gear mechanism 1 Motor shaft 2 Bearing Minute shaft 3 Bearing Minute s...

Page 10: ...RAND URFABRIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Internal connection diagram 078906 00 230 VAC 50 60 Hz 24V DC reversin...

Reviews: