background image

 

 

Dokument:  1597en06.doc 

 

Förf.:  LT/JJo 

 

 

Datum:  2017-11-30 

 

Sida:  6 av 9 

 
 
 

WESTERSTRAND URFABRIK AB 

 

 

 

Box 133 

Tel.  0506 48 000 

 

Internet:  

www.westerstrand.se 

545 23  TÖREBODA 

Fax. 0506 48 051 

 

E-mail: 

 [email protected]

 

6. Resetting / Setting of correct time. 

 
In the example below we describe setting of time to 13:15. starting from the settings actual at delivery, that is 
12:00. 
 
Disconnect  connection to 230V. 
 
1.

 

Disconnect the wire from masterclock (plug at 7). Observe how the connector is applied. 

 
2.

 

Check that the arm of the micro switch (10) is in the same position as 10 B on the sketch, 
-If it does, continue to point 3. 
-If not (which means the arm is in position 10 A) carry on as follows: 
 
Turn wheel (2) clockwise or anti-clockwise until the arm of the micro switch enters  
the notch, position 10 B in the wheel underneath the curve (11). Check so that the pin (3) has position 
straight above the hole (4) . Proceed to p.4 below. 

 
3.

 

Move the brass wheel (2) slightly anti-clockwise until pin (3) is straight over hole (4). 
 

4.

 

Press the P-arm (5) so the pin (3) enters hole (4) and keep it pressed down. This release the synchronous  

     motor. 

 
5.

 

Check that the arrow (6) points straight to 0-mark on the setting plate (1). If not turn theminute wheel (9) 
anti-clockwise until that position. 
When the red arrow (6) points at 0 on the setting plate (1) this means that the movement is 
set to full hour, (the minute hand pointing at 12 and the hour’s hand pointing at full hour 12). 

 
6.

 

Press the P-arm (5) again. 

 

7.

 

Turn the minute wheel (9) anti-clockwise. In this example first a full turn around, then continue until the 
arrow (6) points straight to minute mark 14 on the setting plate (1). 

 
8.

 

Check correct time for synchronisation to master clock. 

 
9.

 

Connect impulse wire (7) from master clock. Note! Apply the connector correct. 

 
10.

 

Connect 230V mains. 

 
11.

 

Wait for the right minute impulse. (In this example for stepping forward to odd minute) 

 
12.

 

When the minute impulse comes from the master clock the setting plate (1) is 
moving one mark clockwise and the hands are moving 1 minute forward. 
The clock now shows 13:15 and it is synchronised to the master clock. 
If the movement does not step forward within this odd minute the connection (7) is wrongly polarized. 
Adjust by repeat the procedure from p.1 to p.5 above. 
Turn the movement manually to even minute (e.g.16) by turning the minute wheel (9) anti-clockwise. 
Release the P-arm (5) 
Turn the connection (7) the other way around and repeat procedure from p.9 above. 

 

Summary of Contents for 115000-00

Page 1: ...synchronous motor for LMV 3 3 Check of motor before mounting of hands 4 4 Mounting of hands 4 Mounting of hands version 115014 00 LMV UV 5 5 Installation and test 5 6 Resetting Setting of correct tim...

Page 2: ...llector The impulse collector includes an impulse controller which based on a cam and a micro switcher controls the current to the synchronus motor When the contact points of the switcher are closed t...

Page 3: ...051 E mail info westerstrand se 2 Sketch of synchronous motor for LMV 1 Setting plate 8A Terminal for connection 230VAC 2 Drive of brass 8B Terminal for Ground connection 3 Pin 9 Minute drive 4 Hole f...

Page 4: ...be positioned straight under the pin 3 when the P arm 5 is pressed down In this position the red arrow 6 should point straight to the 0 mark on the graded disc 1 If so continue mounting the hands see...

Page 5: ...Connect to 230 VAC via the terminal 8A and protective earth to terminal 8B When installed a readily accessible disconnect device shall be incorporated in the fixed wiring 2 Connect the impulse wire f...

Page 6: ...w 6 points straight to 0 mark on the setting plate 1 If not turn theminute wheel 9 anti clockwise until that position When the red arrow 6 points at 0 on the setting plate 1 this means that the moveme...

Page 7: ...he movement begins to forward the hands to correct time It will take some minutes the time depends on how long the power failure has lasted until the movement has reset the hands After the movement ha...

Page 8: ...RIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Lubrication of driving mechanism 1 Angle gear bearing 2 Centre shaft 3 Impuls co...

Page 9: ...B Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Lubrication of gear mechanism 1 Motor shaft 2 Bearing Minute shaft 3 Bearing Minute s...

Page 10: ...RAND URFABRIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Internal connection diagram 078906 00 230 VAC 50 60 Hz 24V DC reversin...

Reviews: