background image

 

 

Dokument:  1597en06.doc 

 

Förf.:  LT/JJo 

 

 

Datum:  2017-11-30 

 

Sida:  5 av 9 

 
 
 

WESTERSTRAND URFABRIK AB 

 

 

 

Box 133 

Tel.  0506 48 000 

 

Internet:  

www.westerstrand.se 

545 23  TÖREBODA 

Fax. 0506 48 051 

 

E-mail: 

 [email protected]

 

Mounting of hands version 115014-00 LMV-UV 

 
1.

 

Mount the movement to the gear for the hands. 

 
2.

 

Mount the hand(s) on the shaft with needlepoint(s) aming straight to 12. 

 
3.

 

Fasten the hour hand(s) carefully. 

 
4.      Mount the minute hand(s) on the shaft with needlepoint(s) aiming straight to 12. 
         

IMPORTANT!

 There should be some space on the shaft between the minute- and hours hand. 

5.      Fasten the minute hand(s) carefully. 
 
 
 

5. Installation and test. 
 

1.

 

Connect to 230 VAC via the terminal (8A) and protective earth to terminal (8B). When installed a readily 
accessible disconnect device shall be incorporated in the fixed wiring.  

 
2.

 

Connect the impulse wire from the master clock via the plug inclosed in delivery. 

 
3.

 

Check that the movement setting remains on full hour, e.g the red arrow (6) points straight to 0-mark.  

 
4.

 

Connect the plug to the movement at (7). 

 
5.

 

Switch on the mains. 

 
6.

 

Wait for a minute impulse for step forward to odd minute. 

 
7.

 

Now the setting plate (1) should turn one mark anti-clockwise and the hands are moving one minute forward. 
- If so, the movement are ready for operation. 
- If not, the connection to impulse (7) is wrongly polarized. Adjust as follows: 
 
A. Disconnect mains 
B. Tur the connector to impulse around or swap wires in the connector.  
C. Check procedure from step 3 above. 

 
 

Summary of Contents for 115000-00

Page 1: ...synchronous motor for LMV 3 3 Check of motor before mounting of hands 4 4 Mounting of hands 4 Mounting of hands version 115014 00 LMV UV 5 5 Installation and test 5 6 Resetting Setting of correct tim...

Page 2: ...llector The impulse collector includes an impulse controller which based on a cam and a micro switcher controls the current to the synchronus motor When the contact points of the switcher are closed t...

Page 3: ...051 E mail info westerstrand se 2 Sketch of synchronous motor for LMV 1 Setting plate 8A Terminal for connection 230VAC 2 Drive of brass 8B Terminal for Ground connection 3 Pin 9 Minute drive 4 Hole f...

Page 4: ...be positioned straight under the pin 3 when the P arm 5 is pressed down In this position the red arrow 6 should point straight to the 0 mark on the graded disc 1 If so continue mounting the hands see...

Page 5: ...Connect to 230 VAC via the terminal 8A and protective earth to terminal 8B When installed a readily accessible disconnect device shall be incorporated in the fixed wiring 2 Connect the impulse wire f...

Page 6: ...w 6 points straight to 0 mark on the setting plate 1 If not turn theminute wheel 9 anti clockwise until that position When the red arrow 6 points at 0 on the setting plate 1 this means that the moveme...

Page 7: ...he movement begins to forward the hands to correct time It will take some minutes the time depends on how long the power failure has lasted until the movement has reset the hands After the movement ha...

Page 8: ...RIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Lubrication of driving mechanism 1 Angle gear bearing 2 Centre shaft 3 Impuls co...

Page 9: ...B Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Lubrication of gear mechanism 1 Motor shaft 2 Bearing Minute shaft 3 Bearing Minute s...

Page 10: ...RAND URFABRIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Internal connection diagram 078906 00 230 VAC 50 60 Hz 24V DC reversin...

Reviews: