1. General description of movement LMV 

 
The movement LMV is based on a 230V synchronous motor which moves the hands every minute via an 
echange gear mechanism. 
The movement is driven by 24V reversing impulses from a master clock, which are collected by a special  
Device, so-called impuls collector. 
The impulse collector includes an impulse controller which based on a cam and a micro switcher controls the 
current to the synchronus motor. When the contact points of the switcher are closed the motor starts. The LMV 
movement has a minute graded disc which indicates the position of the minute hand. This arrangement enable 
setting of correct time. 
The hour hand has not this feature and thus the position of the hour hand has to manually calculated and 
adjusted.  
 
The version LMV-UV complies to the feature and performance of LMV version with the exception that this 
movement only has one shaft for minute drive. This version is used for installations with separate gear for the 
hand. 
 
 
 
 
 
 
 

 

Summary of Contents for 115000-00

Page 1: ...synchronous motor for LMV 3 3 Check of motor before mounting of hands 4 4 Mounting of hands 4 Mounting of hands version 115014 00 LMV UV 5 5 Installation and test 5 6 Resetting Setting of correct tim...

Page 2: ...llector The impulse collector includes an impulse controller which based on a cam and a micro switcher controls the current to the synchronus motor When the contact points of the switcher are closed t...

Page 3: ...051 E mail info westerstrand se 2 Sketch of synchronous motor for LMV 1 Setting plate 8A Terminal for connection 230VAC 2 Drive of brass 8B Terminal for Ground connection 3 Pin 9 Minute drive 4 Hole f...

Page 4: ...be positioned straight under the pin 3 when the P arm 5 is pressed down In this position the red arrow 6 should point straight to the 0 mark on the graded disc 1 If so continue mounting the hands see...

Page 5: ...Connect to 230 VAC via the terminal 8A and protective earth to terminal 8B When installed a readily accessible disconnect device shall be incorporated in the fixed wiring 2 Connect the impulse wire f...

Page 6: ...w 6 points straight to 0 mark on the setting plate 1 If not turn theminute wheel 9 anti clockwise until that position When the red arrow 6 points at 0 on the setting plate 1 this means that the moveme...

Page 7: ...he movement begins to forward the hands to correct time It will take some minutes the time depends on how long the power failure has lasted until the movement has reset the hands After the movement ha...

Page 8: ...RIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Lubrication of driving mechanism 1 Angle gear bearing 2 Centre shaft 3 Impuls co...

Page 9: ...B Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Lubrication of gear mechanism 1 Motor shaft 2 Bearing Minute shaft 3 Bearing Minute s...

Page 10: ...RAND URFABRIK AB Box 133 Tel 0506 48 000 Internet www westerstrand se 545 23 T REBODA Fax 0506 48 051 E mail info westerstrand se Internal connection diagram 078906 00 230 VAC 50 60 Hz 24V DC reversin...

Reviews: