Lit. No. 72131, Rev. 00
July 15, 2018
16
OPERATING THE HOPPER SPREADER – CAB CONTROL
CAB CONTROL
–
SETUP PROCEDURES
Calibrate the Empty Hopper Setting
(
Cb
and
EH
Codes)
Calibrating the empty hopper setting enables the
cab control to alert the operator when the hopper
is empty.
Recalibrate the empty hopper setting at the start of
each ice-control season.
1. Ensure that the hopper is empty before
beginning the calibration.
2. Turn the vehicle ignition to ACC or ON. Press
the ON/OFF button on the cab control to turn
the control ON.
3. Press and hold the Material Width (left) knob
for approximately 10 seconds until the
Cb
code
displays.
4. The calibration cycle will begin. The blue
LEDs around the Material Flow (right) knob will
illuminate in succession until all eight are lit.
5. When the automatic calibration cycle is
complete, the control will automatically revert
to the previous material application settings.
Adjust LED Brightness Level
(
LS
and
SL
Codes)
The brightness setting of the cab control lights
can be adjusted from 1 to 16. The factory default
setting is 8.
1. Turn the vehicle ignition to ACC or ON. If
necessary, press the cab control ON/OFF
button to turn the control OFF.
2. Press and hold the Material Width (left) knob
for approximately 3 seconds until the
LS
code
is displayed.
3. Release the knob and turn it clockwise or
counterclockwise to increase/decrease the
brightness level. The light level number will
show in the status display.
4. After selecting the desired brightness level,
wait a few seconds for the
SL
con
fi
rmation
code to display.
NOTE: A brightness level setting of 12
or higher is recommended for daylight
conditions.
If the control is turned OFF or loses power during
the calibration cycle, the calibration data will be
lost. Make sure that the control is ON and restart
the calibration process at Step 3.
Once the empty hopper setting has been
calibrated, the
EH
code will
fl
ash on the display
and a beep will sound whenever the hopper is
empty. The
EH
code is informational only and will
not stop spreader operation.
Clearing Empty Hopper Calibration Data
(
Cc
Code)
The empty hopper calibration may be cleared, if
desired. The control will no longer display the
EH
status code when the hopper is empty.
Start the calibration cycle as described above. At
Step 4, press the Material Flow (right) knob during
the calibration cycle to clear
all
calibration data.
The
Cc
(Clear Calibration) code will display and the
control will exit
Cc
mode automatically.
Summary of Contents for LOW-PRO 300W
Page 2: ......
Page 19: ...Lit No 72131 Rev 00 July 15 2018 17 POLY HOPPER SPREADERS ...
Page 39: ...Lit No 72131 Rev 00 July 15 2018 37 STAINLESS STEEL HOPPER SPREADERS ...
Page 73: ...Lit No 72131 Rev 00 July 15 2018 71 SPREADER ACCESSORIES ...
Page 84: ...Lit No 72131 Rev 00 July 15 2018 82 Tailgate Spreaders ...
Page 94: ...Lit No 72131 Rev 00 July 15 2018 92 Low Profile Tailgate Spreaders ...
Page 99: ...Lit No 72131 Rev 00 July 15 2018 97 Low Profile Tailgate Spreaders ...