4. Install the new fuse in the fuse holder.
a) Insert the fuse into the fuse holder cap, and position the
cap in the fuse holder with the slot on the cap in the
vertical position.
b) Insert the screw driver into the slot, apply slight
pressure, and turn the cap 1/4 turn clockwise, or until
you feel the cap lock into position. The slot on the fuse
holder cap should be in the horizontal position.
5. Replace the power cable and power the unit ON. If the unit
still does not register power, contact WTI Technical Support
for further assistance.
6.3.
110V / 220V Operation
Unless otherwise specified at time of order, the PollCat III will be
shipped from the factory configured for 110 VAC operation. To
configure the unit for 220 VAC operation, proceed as follows:
1. Power OFF the PollCat III and remove the power cable.
2. Locate the AC Switch on the PollCat III Back Panel.
Figure 2.2 describes the AC Switch location.
3. Insert a small, flat tip screw driver into the slot on the AC
Switch. Slide the AC Switch to the right (towards the fuse
holder). The AC Switch will now indicate 220V operation.
Note:
When configuring unit for 110V operation, slide the
switch to the left.
4. Replace the Power Cable and power ON the PollCat III. The
unit is now ready for operation.
6-3
Power Supply